User Guide
Copyright © Fluid Products Pty Ltd 2012
PRO SERIES Drinking Water Systems
USER GUIDE
3
CARTRIDGE INSTALLATION/CHANGEOUT
To change the filter cartridges adhere to the following procedure.
1.
Close Ballvalve to prevent water flow
2.
Unscrew Filter Housing using the spanner wrench and discard cartridges. When removing
housings place a container underneath to catch any spillage. Membrane housing cap can be
unscrewed by hand.
3.
Cleanse the inside of the housing using Puretec S500 Sanitiser. Check O-Ring and lubricate
with food grade silicone lubricant or similar. Replace O-Ring if kinked or damaged.
4.
Install new cartridges and replace housing screwing them up HAND TIGHT ONLY. PX051 filter is
on the inlet side and CB951 on the outlet side.
5.
Restore water supply & check for leaks, rectifying them, if any, before leaving the unit.
After installing cartridges flush unit for 5 - 10 minutes.
INSTALLATION
INSTALLATION REQUIREMENTS
1.
Supply pressure:
300 - 600kPa.
2.
Supply temperature:
3°- 30°C.
PRO SERIES