background image

3

 

Inline Undersink Filter System User Guide

Installation Requirements

1. 

15mm (½”) cold water line.

2. 

Min/Max pressure: 100 - 520 kPa.

3. 

 Min/Max temperature 0° - 38°C (protect from freezing).

4. 

 Suitable location for faucet.

Alternative fittings may be required if being connected to anything other than 15mm (½”) copper 
pipe. No electrical or drainage requirements needed.

Note: Where line pressure exceeds 500 kPa, an approved pressure limiting device must be 
installed to comply with Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1-
2003, Clause 3.3.4)

Installation Procedure

1. 

Select suitable location for filtered water to be delivered (eg. sink). Remember to allow 
access room for changing filters and a suitable place where water spillage will not 
cause damage. Location should not be in direct sunlight.

2. 

Isolate water supply and cut copper pipe ready to install the connection tee.

3. 

Connect the ballvalve, pressure limiting valve and push-fit connector together with 
thread tape. Flush a small amount of water to remove any debris.

4. 

Choose the best position for the faucet, taking into consideration height of jugs etc. 
and also the drainage of any spills. Then drill a 12mm hole and install the faucet as in 
step 5.

5. 

To install the faucet, connect the base of the faucet to the spout. Feed the escutcheon 
and O-ring over the threaded end of the faucet (see figure 2, pg.6). Insert the threaded 
end into the hole in the sink or bench. Feed the plastic washer, lock washer, locking nut, 
gasket, cone washer and ¼” compression nut onto the threaded end and tighten the 
nuts, ensuring the faucet is correctly positioned above the benchtop.

6. 

Install housing assembly by positioning it in the desired location, marking the position 
of fixing holes and fixing with bracket screws (IL-UB Series can be mounted horizontally 
or vertically). Allow room for the connecting tubes and for removing the filter bowls 
(50mm).

7. 

Fit tubing into connectors (for quick-connect fittings see figure 3, pg. 7). Allow slack in 
the tubing. Ensure flow arrow on cartridge is in direction of waterflow. 

8. 

Install cartridge as per Cartridge Installation/Replacement.

9. 

Restore the water supply and check for leaks. The filters need to be only hand tight. If 
they leak then undo housing and check the O-ring is seated properly.

Installation

Summary of Contents for IL-UB Series

Page 1: ...For correct operation installation it is essential to observe these instructions JAN2022 User Guide Inline Undersink Water Filtration System IL UB Series ...

Page 2: ...on use more than 2 days For a period of non use of 2 weeks or more it may be necessary to replace cartridge Cartridge Replacement To maintain the high quality of the purified water the cartridges need changing every 6 months this is dependent on water quality and usage You can obtain replacement cartridges from your local Puretec dealer To maintain performance and warranty use genuine Puretec repl...

Page 3: ...st position for the faucet taking into consideration height of jugs etc and also the drainage of any spills Then drill a 12mm hole and install the faucet as in step 5 5 To install the faucet connect the base of the faucet to the spout Feed the escutcheon and O ring over the threaded end of the faucet see figure 2 pg 6 Insert the threaded end into the hole in the sink or bench Feed the plastic wash...

Page 4: ...aving the unit 7 After installing cartridges flush unit for 5 10 minutes User Guidelines Minimum operating pressure 100 kPa Maximum operating pressure 520 kPa Protect from freezing Maximum operating temperature 38 C Maximum flow rate 1 9 Lpm This system must be installed according to local plumbing codes on the cold water line Replacement Cartridges See Cartridge Installation Replacement section T...

Page 5: ...5 Inline Undersink Filter System User Guide Figure 1 Installation Faucet Tubing 1 4 White Inline Cartridge with Quick Connect Fittings Pressure Limiting Valve Multivalve Ball Valve Cold Water Line ...

Page 6: ...ation Operation Manual Copyright Puretec Pty Ltd 2018 Figure 2 Installation Faucet Escutcheon Lock Washer Gasket 1 4 Compression Nut Counter Top ø12 5 hole Plastic Washer Locking Nut Cone Washer 1 4 Tube O Ring ...

Page 7: ...ed as a guide only The complete range of Puretec products are developed refined and made to meet and exceed stringent specifications for the worldwide market Important Note Sales of products are subject to our Terms Conditions which are available upon request All specifications prices and photos are a guide only and are subject to change without notice Please ring to confirm details Do not use pro...

Page 8: ...y your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to place of purchase for consideration Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This warranty is provided in addition to other rights and remedie...

Reviews: