UV Lamp Installation/Replacement
UV Lamp Installation / Replacement
Prior to performing any work on the UV steriliser system, always disconnect the power
supply and allow unit to cool.
The treated water will seem warm for a short period at first
flow. This is because the UV lamp emits heat to kill bacteria. When turning on a tap, let the
water run for a short time to purge any warm water.
Warning: Do not look directly into ultraviolet rays emitted from the UV lamp as they
will cause serious burns to unprotected eyes.
1.
Isolate the water to the unit and release the water pressure by opening up the mixer tap.
2.
Place a container below the unit, in case of drips.
3.
Slowly pull the black the black lamp cap off, being careful not to detach the lamp inside. Do
not use a twisting motion as this will unscrew the aluminium nut underneath, simply pull
outward. Re-tighten the aluminum nut once the lamp connector is removed, if required.
4. Remove the old lamp from the connector and dispose of accordingly.
5.
Remove the new lamp from its packaging and insert the metal prongs into the lamp
connector.
6.
Carefully re-insert the lamp back into the chamber and securely fit the black lamp
connector back onto the metal nut.
7.
Turn the water on, let the water flow through & check for leaks.
8.
Turn the power on and ensure that the lamp is operating. Make sure that the GREEN LED is
illuminated.
Aluminium
Nut
Water Outlet
O-Ring
Lamp Power
Connector
Quartz
Sleeve
UV Lamp
Aluminium
Nut
Cap
Ballast
Stainless Steel
Chamber
O-Ring
Water Inlet
Fig. 8