background image

SAFETY PRECAUTIONS

WARNING! To protect against electric shock, do not immerse the humidifier, power cord or power plug in water or allow
 moisture  to come in contact with these parts.

IMPORTANT

The transducer, filter and basin should be cleaned regularly. Please refer to the cleaning and maintenance.

■ 

Use proper voltage AC 220~240V 50Hz in UK and Europe. Use of improper voltage may cause fire hazard or electric shock.

■ 

Do not use in areas where flammable or explosive materials are stored.

■ 

Do not place this device in direct sunlight or near objects that generate high temperature heat. The heat may cause deformation

or warping of the outer casing. Do not operate the unit without water in the basin.

■ 

Do not insert foreign objects into the device. Do not touch the transducer or the lower water basin when the unit is operating.

■ 

Do not scratch the transducer.

■ 

Do not submerge this device in water. Water or cleaning liquids may only be used on parts to be cleaned according to the

cleaning and maintenance instructions.

■ 

Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer. Do not use any harsh detergent s

that may damage the unit.
If you smell an abnormal odour please turn off and unplug the unit and call PureMate technical support.

■ 

Do not use fabrics or other materials to cover this device. Obstructed air inlets and outlets will result in improper operation of this

unit and may result in fire or other damage.

■ 

Do not plug in or pull out the power cable with wet hands. Do not disassemble the base unit. Before cleaning and maintenance,

the appliance must be disconnected from the main supply. Do not touch water and components in the water basin when the unit is
working.

■ 

Do not allow children to play with any product packaging, such as plastic bags.

To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves, or heaters.

■ 

Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet.

■ 

DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or

damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.

■ 

Use appliance only for intended household use. DO NOT use outdoors.

■ 

Always place humidifier on a firm, flat, level surface at least 60cm away from the floor.

■ 

DO NOT allow the moisture outlet to directly face the wall.

■ 

Humidifier should be unplugged when not in use.

■ 

DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside

of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

■ 

Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier

OFF.

■ 

The inner ultrasonic transducer is highly sensitive. Do not touch it with bare fingers or scrape it with metal tools, or it will reduce

mist output. When cleaning this area please use a small cleaning brush, cotton swab or toothbrush. Do not use hot water as it
may damage the missing parts.

■ 

Children should be supervised to ensure that they do not play with the appliance.

To prevent interference and damage to other electronic devices, this machine should be placed at least 1 meter away from a
computer, television, radio or other electronic equipment.

■ 

For safety reasons and to prevent fire or electric shock, unplug the power cord from the electric outlet socket whenever you:

 

- Do not use the device for a long period of time.

 

- Remove the tank, clean or service the machine or the permanent filter.

 

- Move or transport the device.

If the power cord is damaged, then it must be replaced by a qualified person to prevent electric shock or fire.

PM 805 

U

ltra

s

onic Humidifier

PUREMATE

English   2

Summary of Contents for PM 805

Page 1: ...FIER WITH IONISER AND AROMA FUNCTION IMPORTANT DO NOT USE ESSENTIAL OILS DIRECT INTO WATER TANK THIS WILL CAUSE THE HUMIDIFIER TO MALFUNCTION AND RESULT IN WARRANTY BEING VOID DO NOT USE ANY OILS WARN...

Page 2: ...t the cord under rugs near heat registers radiator stoves or heaters Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet DO NOT operate any appliance with...

Page 3: ...Air Outlet Transducer Buoy Indicator Lamp Touch Button Nozzle 2 TOUCH BUTTON ON OFF HEATING ION NOTE Sleeping Mode Press and hold the ON OFF button for 3 seconds the machine will enter into Sleeping...

Page 4: ...be warmer as compared to the room tempera ture due to health and safety issues The warm mist light indicator is on and if you place your hand over the top outlet you may feel the warm mist INSTRUCTION...

Page 5: ...e surface of the transducer 3 Rinse the transducer with clean water 4 Never use sharp or solid objects for cleaning the transducer How to clean the water basin 1 Clean the water with a soft damp cloth...

Page 6: ...the water tank and make sure that it sits properly The volume of spray mist is too low Too much mineral scale in the water basin Clean transducer Water is too dirty or water was kept too long in the t...

Page 7: ...services WHAT YOU MUST DO 1 Contact PureMate customer Service at 44 121 270 9423 www PureMate co uk for Return Authorization Number 2 Pack the product in its original carton and in the same manner in...

Page 8: ...er Components 1 Front View 4 Remove Top Cover 5 Lifting Water Tank 6 Unscrew Tank Lid Cap 7 Filling Water Tank 8 Screw Tank Lid Cap 9 Placing Water Tank on Machine 3 Cleaning Transducer HELPFUL TIPS P...

Reviews: