11
LOG BED
Page 1: ...EGLOW LIMITED This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given...
Page 2: ...fuse approved to BS 1362 The fuse cover of a moulded on plug must be refitted when changing the fuse should it be lost the plug must not be used until the correct replacement fuse cover is obtained f...
Page 3: ...to assist removal FIREPLACE INSTALLATION THIS FIRE MUST BE INSTALLED IN A FIREPLACE OPENING AND SECURED USING APPROPRIATE WALL FIXINGS Your PUREGLOW fire is designed to fit a standard 16 410mm firepl...
Page 4: ...he membrane pad situated next to the thermostat With the mains supply con nected to the fire and switched on the fire can be operated By pressing the ON OFF FUNCTION button the features of the fire ca...
Page 5: ...sh For difficult to remove marks such as finger marks it is recommended that a slightly damp chamois leather is used Care should be taken when cleaning around metal parts non painted metal parts may h...
Page 6: ...Should this occur follow the points below 1 Switch the fire off at the wall outlet 2 Ensure that there are no obstructions in or around the air inlet see Fig 1 3 After approximately 5 minutes switch...
Page 7: ...Fig 4 the ashpan and fuel bed can now be fitted see Section 6 for fuel bed layout ANNABELLE CHLOE JULIET CASTINGS The casting complete with magnets is positioned as shown in Fig 5 below and moved towa...
Page 8: ...has been fitted or if the Fire was supplied with the Canopy fitted the Fire back should be fitted to the Fireplace using suitable fixings Double sided tape or Silicon sealant should be used if fitted...
Page 9: ...if the fire is NOT fixed into the fireplace FITTING THE FRET The fret is fitted as shown on the diagram right care should be taken when positioning the fret to make sure that the fireplace hearth is n...
Page 10: ...e the transit tape which holds the Fuel bed and back panel in place during transit and fitting The Log bed is also supplied with loose logs that are laid out after the above is complete see Log bed as...
Page 11: ...11 LOG BED...
Page 12: ...o the coal bed and are not intended to be removed individually 3 Loosen fuel bed locater screws allowing tabs to rotate down 4 Remove the fuel bed 5 Bend rear panel location tabs forward to release th...
Page 13: ...USED AS SHOWN ABOVE WITH THE STABILITY BRACKET INSTALLED WHERE POSSIBLE THE FIRE SHOULD BE INSTALLED AS SHOWN BELOW USING THE WALL HANGER BRACKET THE WALL HANGER BRACKET SHOULD BE FIXED TO THE WALL U...
Page 14: ...commercial waste at the end of its working life The Waste of Electrical and Electronic Equipment WEEE Directive 2002 96 EC has been put in place to recycle products using best available recovery and r...
Page 15: ...sted Please do not send a photocopy Pure Glow Limited are not responsible for any cost incurred by the customer in returning the product to the seller When making a claim under warranty you must provi...
Page 16: ...art No I01448 issue A Packing list Model Type Pureglow XPG 2kW Mains Lead Batteries Remote Handset Packed By Affix Second Data Label HERE Date Log bed Logs x4 Coal bed Back panel brick reed Packed By...