background image

SAVE THESE INSTRUCTIONS!

- This product is for indoor locations only.
- This instructions shows a typical installation.
- Before beginning any electrical work, ensure that the 
  power to the electrical box is off.

IMPORTANT INFORMATION

1718 W. Fullerton Chicago, IL 60614
Ph: 773.770.1195 ● Fax: 773.935.5613
www.PureEdgeLighting.com ● [email protected]
© 2016 PureEdge Lighting. All Rights Reserved. 

Doc # 904-TR24-EP1-1RE_05

Installation Instructions for 

TruTrack End Power Feed with 1"

Rectangle Junction Box

TR24-EP1-1RE-_-_-WH

Section One: Install the Junction Box

1

1:

 Mount each adjustable mounting bar to one side of the junction box and secure them with the mounting brackets and 

    Phillips screws provided.

A

B

ADJUSTABLE
MOUNTING BAR

#8 SCREWS

ADJUSTABLE
MOUNTING BAR

CONDUIT

3

2

MOUNTING
BRACKET

PHILLIPS SCREW

JUNCTION BOX

1

PHILLIPS SCREW

1

MOUNTING
BRACKET

ADJUSTABLE
MOUNTING BAR

JUNCTION BOX

HORIZONTAL ORIENTATION

VERTICAL ORIENTATION

NOTE:

 

Only use 0-10V and Uni power supplies with this 

product. See the wiring diagram provided with the power supply 
instructions.

2:

 Place the adjustable mounting bar tabs against the ceiling 

    joists. Secure the adjustable bars to the joists with the #8 
    screws.

3:

 Install conduit (if required by local electrical code) and run 

    the low voltage wires coming from the remote power supply 
    to the junction box.

NOTE:

 

Adjustable mounting bars mount to studs that are 

spaced 14.5" to 25" apart.