Routine Care & Maintenance 

1. Filter replacement and maintenance schedule 

Filters need to be replaced or maintained properly to maximize the unit’s performance.
Maintenance schedule is based on pollution level. Following is the recommended maintenance schedule
for most environments. Filters need to be replaced/cleaned more often if unit is being used in a heavily 
polluted environment: 

2. Filter replacement and maintenance 

Replaceable VOC pre-filter  - replace every 6 months
Cleanable Poly Mesh Pre-filter and High Energy Grid  -  clean every 3 months
Main filter  -  replace every 9-12 months
VOC post-filter  -  replace every 6 months

WARNING: When DFS needs service, dirt in the high energy grid can create a short circuit. The 
power supply PCB shuts off and the RED indicator turns on. Turn the unit off and unplug it; then 
perform maintenance as indicated in the 

Filter replacement and maintenance 

section below.

WARNING: The unit should be turned off, unplugged and the motor should completely stop 
before any maintenance. 

2-1  Pre-filter set maintenance 

• Remove the front cover of main unit by grabbing both sides of about 1/3 of the distance from 

the bottom and pulling the bottom part away from the main body of the unit. (Fig 3-1)

• When the bottom of the front cover is a few inches away from the main body, use both 

hands to pull the front cover down slowly to disable child lock on top of the front cover. (Fig 3-2) 

6

Summary of Contents for KJ468F

Page 1: ...USER MANUAL Ultrafine Professional Multistage Air Purification System with DFS Technology...

Page 2: ...Color options vary depending on region market...

Page 3: ...nce at ultrafine particle levels Your choice of the Pure Ultrafine series will bring pure air and create a healthier indoor environment for you and your loved ones Now let s get started Table of Conte...

Page 4: ...gh Microbiostasis fig 1 component 4 6 Proprietary Blend VOC post filter Innovative VOC adsorption filter for removal of harmful gases and odors with 90 removal efficiency on Formaldehyde and 95 remova...

Page 5: ...6x13 4 in Weight 27lbs Exploded View Specifications 1 Front screen 2 VOC Pre filter 3 Cleanable integrated pre filter 4 High energy grid 5 Safety lock 6 Main filter 7 VOC Post filter 8 Top cover User...

Page 6: ...enance to remove the filters un wrap and replace them in the unit Filters include VOC Pre filter Main Filter and VOC Post filter Inspect the power cord for damage If the power cord is damaged please c...

Page 7: ...Mode button to activate Turbo Mode 2 When activated all buttons on the UI are illuminated white 3 To deactivate Turbo Mode touch anywhere in the speed bar FILTER INDICATOR 1 2 3 1 When unit is operat...

Page 8: ...ths VOC post filter replace every 6 months WARNING When DFS needs service dirt in the high energy grid can create a short circuit The powersupplyPCBshutsoffandtheREDindicatorturnson Turntheunitoffandu...

Page 9: ...zontal gently pull out the High Energy Grid and put aside on a secure clean and dry surface FIG 7 Use a clean microfiber cloth to wipe off the dust on the High Energy plate and High Energy Wires If Hi...

Page 10: ...stall the High Energy Grid following steps described above in the same section Point 2 2 High Energy Grid maintenance WARNING The appliance is not to be used by children or persons with reduced physic...

Page 11: ...replacing cleaning filters 3 1 Reset pre filter indicator Hold filter 1 VOC pre filter indicator for at least 5 seconds to reset timer 3 2 Reset main filter indicator Hold filter 2 main filter indicat...

Page 12: ...lter indicator is out and Change pre filter indicator is illuminated in red replaceable VOC pre filter needs to be replaced and cleanable pre filter needs to be cleaned 5 Main filter indicator is out...

Page 13: ...lies only to the repair or replacement of any manufactured or supplied part of this product which upon inspection by Pure authorized personnel proves to have failed in normal use due to defects in mat...

Page 14: ...imited Warranty does not apply to re placeable filters and high energy grid wires Limitations Pure shall not be liable for property incidental and or consequential damages of any kind and unless other...

Page 15: ...Filter Replacement Schedule DATE FILTER NOTE...

Page 16: ......

Reviews: