The boiling tank 

 lls to normal operating level, but the heating 

element will not heat or bring water to a boil.

If the heater reset is not popped or the fan is running and the boiling tank is full of
water, you may have a defective heating element.

If water continues to 

 ll the boiling tank a

ft

 er draining the tank, and the fan isn’t op-

erating either, then you may have a defective outside boiling tank microswitch. Check
with a volt/ohm meter.

Make sure the 

 oat is operating correctly and not stuck at bottom of tank.

Check all wiring connections on the control relay. Inspect for any burnt or damaged
wires on the relay. Check the relay with a volt/ohm meter.

The boiling tank over

 ows with water.

If the 

 oat actuating arm is depressing the inside microswitch and the 

 oat rod is

moving freely and 

 oats accordingly with the water level, you may have a defective 

microswitch. Check with a volt/ohm meter.

If the microswitch checks out ok, and the heating element and fan come on, then you 
need to replace the relay. Check with a volt/ohm meter.

If the microswitch and relay check out ok, then you may have a defective solenoid.
Turn the power switch to “OFF”. If water continues to 

 ow into the boiling tank, then

you need to replace the solenoid.

If the 

 oat ball is heavy and has scale build-up, clean the boiling tank and, if neces-

sary, replace the 

 oat.

If the 

 oat is not moving freely, you may need to install a new bushing and o-ring or

 oat repair kit.

If the 

 oat ball is full of water, replace the 

 oat ball.

Machine does not shut o

  when storage tank is full.

Check that the Storage Tank 3 pin wire harness is properly connected.

Connect the 3 storage tank probes together.  If the unit does not shut down, then
replace the level control circuit board.

The unit runs a short time and the heater reset pops.

Note: 

If the reset is popped, use the eraser end of a pencil to reset it.

If the boiling tank water level is below the heating element, the 

 oat may be sticking

and you may need to adjust the 

 oat or install a new bushing and o-ring or 

 oat repair

kit.

If the unit starts up a

ft

 er it is cooled, you may have a faulty reset.

How Your Distiller Works

The Pure Water AquaNui is designed to produce high purity distilled water.  There are 
three production levels depending on the model that was ordered:

1000 Watt Heating Element .........................................approximately 8 gallons per day.

1200 Watt Heating Element .......................................approximately 10 gallons per day.

1500 Watt Heating Element  .......................................approximately 12 gallons per day.

The Pure Water AquaNui  is a fully automatic unit. The water level in the boiling tank 
is controlled by a 

 oat and microswitches and the storage tank is controlled by level 

sensing probes.

The boiling tank operates on a modi

 ed batch approach. Feedwater is automatically 

added until a high level is reached and this triggers the heating element and fan to 
operate. This begins the distillation cycle.

As the unit distills, the water level in the boiling tank falls. When the water level gets 
close to the heating element, the low-level microswitch is triggered, causing feedwa-
ter to be added until the high level is reached. If, for some reason, no water enters the 
boiling tank when needed, the fan and heating element will turn o

  until the condition 

is corrected. 

Once the storage tank is full of distilled water, the unit will automatically shut down. 
The AquaNui will begin distilling again once the water level in the storage tank drops 
by approximately 1.5 Gallons. It continues to operate until the storage tank is full 
again.

There are various storage tank options available.  The standard sizes are 5 gallon ca-
pacity, 10 gallon capacity and 15 gallon capacity.  Other specialty tanks are available.  
If additional storage is desired then additional tanks can be added to increase the 
total storage amount.

The distilled drinking water is drawn from the storage tank through a faucet on the 
front of the tank or through the optional pump.

The AquaNui is equipped with a manual drain valve, which allows the residue from the 
boiling tank to be drained periodically. 

6

15

5

5

8

8

6

6

7

7

Summary of Contents for 21598

Page 1: ...Operator s Manual Models 8G 10G 12G Pure Secure LLC 4511 NW 42nd St Lincoln NE 68524 USA Tel 402 467 9300 Toll Free in the USA 800 875 5915 Fax 402 467 9393 www MyAquaNui com TM ...

Page 2: ...talling the AquaNui Distiller 8 Connecting the Raw Water Line 9 Connecting the Power Cord 10 Start Up 10 Maintenance and Cleaning Overall Maintenance Requirements 11 Cleaning the Exterior 11 Draining the Boiling Tank 11 Cleaning the Boiling Tank 11 Changing the Pre Filter 12 Tank Sterilizing 13 Troubleshooting 14 AquaNui Distiller Parts List 16 AquaNui Distiller Exploded View 17 Storage Tank and P...

Page 3: ...distiller in water or any other liquid NEVER operate the distiller with a damaged cord or allow the cord to become exposed to hot surfaces DO NOT let children play with the distiller DO NOT touch the top of the distiller when it is operating because it may be hot Exercise care when removing the boiling tank and or the boiling tank lid Never remove boiling tank or lid when the distiller is operatin...

Page 4: ...below for future reference Date of Purchase Model Production Rate 8G 10G OR 12G Storage Tank Size Serial Number Included With Your Distiller In addition to your Pure Water AquaNui distiller the distiller box contains 1 4 compression nut 9550 15 of 1 4 food grade tubing 9526 15R VOC Pre lter 21048 Drain extension tube 518 Owners Manual Warranty Card Power Cord The AquaNui Storage Tank box contains ...

Page 5: ...ller Cooling Fan Power Cord Receptacle Power Fan Switches Raw Water Valve VOC Pre lter Overtemperature Reset Boiling Tank Drain Storage Tank 5 Gallon 10 Gallon or 15 Gallon Shown Distilled Water Spigot Pump Outlet Legs Adjustable Feet 5 ...

Page 6: ...ating element the low level microswitch is triggered causing feedwa ter to be added until the high level is reached If for some reason no water enters the boiling tank when needed the fan and heating element will turn off until the condition is corrected Once the storage tank is full of distilled water the unit will automatically shut down The AquaNui will begin distilling again once the water leve...

Page 7: ...esired location 3 Slide a leg onto the storage tank from the bottom Each leg is held on by 4 nuts on the bottom of the storage tank and 2 cap nuts on the side of the tank 4 Screw in the adjustable feet 5 Install the faucet with the gasket 6 Optional Pump Installation a If you have the optional pump install it at this time It is designed so that the end with the ttings extends to the rear of the st...

Page 8: ...nk need to be connected for the distilled water as well as the wire harness for the oats in the storage tank Second the fan blades were secured for shipment and must be released before the distiller is usesd 1 Remove the distiller from the packaging Use a phillips screwdriver to remove the back panel 2 Disconnect the water inlet and steam tubes to the boiling tank 3 Disconnect the two plastic part...

Page 9: ...handle before or during installation Be sure the piercing lance does not protrude beyond the rubber gasket Failure to do this may result in damage to the piercing needle Note The use of softened water for the raw water supply is recommended to minimize scale build up in the boiling tank and drain valve Note The Pure Water AquaNui comes standard with a saddle tapping valve In some areas a saddle ta...

Page 10: ...te the power cord in the parts kit bag Install the female end of the power cord into the outlet on the back of the unit Start Up Notes and Cautions Note This system must be fully grounded at all times The electrical receptacle you use must be a fully grounded single phase AC 115 120 volt 15 amp 220 VAC 7 5 amp minimum circuit If a two pronged wall receptacle is encountered it is the personal respo...

Page 11: ...on the water level in the storage tank Maintenance and Cleaning Overall Maintenance Requirements The following guide should be used for the maintenance of your distiller The timing will vary according to your local water conditions It is your responsibility to maintain your equipment Without proper maintenance your distiller may not produce optimum results The following is an average guide to main...

Page 12: ... Under no circumstances should the cleaning solution be heated and run through a steam sterilization or distillation cycle Note Failure to clean the boiling tank can result in scale build up causing prema ture heating element failure as well as reduced purity of the distilled water due to the possibilities of splash over of contaminants from the boiling tank To clean the boiling tank 1 Turn the Po...

Page 13: ...faucet to completely drain the storage tank 3 Make sure the main power switch is ON 2 Place a cup or small bucket under the storage tank faucet open faucet 3 Turn the fan switch to OFF This will start a Steam Sterilization cycle Steam will now be produced in the boiling tank The steam will pass through the coil but not be cooled The steam will heat up and sterilize the storage tank Allow the disti...

Page 14: ...ith water automatically Note Make sure the saddle tapping valve or utility hook up valve is turned ON to supply the feed water Note The water level in the storage tank must be below 3 4 full before the distiller will start If the oat ball inside the boiling tank is resting against the heat tab and is fully depressing the low level top microswitch you probably need to replace the micro switch Check...

Page 15: ...fan come on then you need to replace the relay Check with a volt ohm meter If the microswitch and relay check out ok then you may have a defective solenoid Turn the power switch to OFF If water continues to ow into the boiling tank then you need to replace the solenoid If the oat ball is heavy and has scale build up clean the boiling tank and if neces sary replace the oat If the oat is not moving ...

Page 16: ...PERATURE 1 4 20 63419 63419 63419 UNION BRASS 1 4 COMP USE DELRIN SLEEVES 21 9550 9550 9550 NUT COMP 1 4 PLASTIC 22 9019 9019 9019 SCREW 8 32 X 3 4 PHD PLPS 23 7197 7231 70106 VALVE SOL 1 4 COMP N C 24 21048 21048 21048 FILTER VOC AQUANUI PREFILTER 25 9541 9541 9541 TUBING 5 8 OD x 3 8 ID 26 9921 9921 9921 CLAMP HOSE WIRE SPRING 5 8 27 21007 02 21007 02 21007 02 PAN BOTTOM STUDDED 28 654 654 654 M...

Page 17: ...AquaNui Distiller Exploded Drawing 17 ...

Page 18: ...9592 LEG LEVELER DISPENSER 8 8014 8014 8014 FILTER AIR 80 MICRON HDPE 9 21025 21025 21025 PROBE ASSY MID AQUANUI 10 21021 21021 21021 PROBE ASSY HIGH AQUANUI 11 95315 95315 95315 FAUCET PLASTIC 3 8 NPT 12 144 144 144 WASHER RUBBER FOR MS FAUCET 13 221 0056 221 0056 221 0056 PLUG SPEEDFIT 3 8 STEM 14 9607 9607 9607 CONN SPEEDFIT 3 8 T X 3 8 M 15 21051 21051 21051 PUMP 120V AQUANUI WITH CORD 16 9614...

Page 19: ...Storage Tank and Pump Exploded Drawing Optional Pump Kit 19 ...

Page 20: ... 2013 Pure Secure LLC US and Foreign Patents Pending Form 21038 TM ...

Reviews: