1. Turn the main power switch to ON.

2. Open the faucet on the storage

tank and place a cup or small
bucket under the faucet.

3. Turn the fan switch to OFF.  This

will start a “Steam Sterilization”
cycle.  Steam will now be pro-
duced in the boiling tank.  The 
steam will pass through the coil,
but since the fan is turned o

 , the steam will not be cooled.  The steam will heat up

and sterilize the storage tank.  Allow the distiller to run for 30-45 minutes.

4. Turn the fan switch to ON.

5. Close the faucet on the storage tank.

6. Allow the unit to 

 ll the storage tank and shut o

 .

7.

Optional Pump: 

 Plug the pump into the wall outlet.

8. Check for leaks.

The unit will now run automatically based on the water level in the storage tank.

Maintenance and Cleaning

Overall Maintenance Requirements

The following guide should be used for the maintenance of your distiller. The 
timing will vary according to your local water conditions. It is your responsibility 
to maintain your equipment. Without proper maintenance, your distiller may not 
produce optimum results. The following is an average guide to maintenance:

Cleaning the Exterior

Use Stainless Steel Polish & Cleaner (stock #6606). It is available online at www.
MyAquaNui.com. 

Draining the Boiling Tank

The AquaNui has a manual drain valve that discards the contaminants and residue 
out of the boiling tank when opened. This minimizes the build-up of scale in the 
boiling tank. 

3. Connect the 5” piece of tubing to the outlet of the Carbon Filter.

4. Connect the remaining 1/4” tubing to the saddle tapping valve.

3. Connect the 1/4” tubing from the saddle tapping valve to the inlet of the carbon

 lter.

4. Rinse the carbon 

 lter:

a. Hold the outlet end of the carbon 

 lter over a drain or bucket.

b. Turn the water on at the saddle-tapping valve.

c. Cycle the water on and o

  until the water exiting the carbon 

 lter is clear.

d. Turn the water supply o

  at the saddle-tapping valve.

5. Install 1/4” tubing from the carbon 

 lter outlet to the solenoid valve inlet on the

back of the distiller.

6. Turn the water supply on at the saddle-tapping valve.

Connecting the Power Cord

Note: On some 240V units, the power cord may be sold separately and is not included in 
the parts kit bag.  

1. Ensure the Power Switch is turned to the OFF position.

2. Locate the power cord in the parts kit bag. Install the female end of the power cord

into the outlet on the back of the unit.

Start-Up

Notes and Cautions:

Note:  

This system must be fully grounded at all times. The electrical receptacle 

you use must be a fully grounded, single phase, AC 115-120 volt, 15 amp (220 VAC, 
7.5 amp) minimum circuit. If a two-pronged wall receptacle is encountered, it is the 
personal responsibility and obligation of the customer to contact a quali

 ed elec-

trician and have it replaced with a properly grounded three-pronged wall recep-
tacle or have a grounding adaptor properly grounded. If an extension cord must be 
used, it should be a 3-wire, 15-amp minimum cord.  

CAUTION:  Do not, under any circumstances, cut or remove the round ground-
ing prong from the electrical plug.  

Your unit now has:

A raw waterline connected and turned on.

A VOC pre

 lter installed

A complete boiling tank with both water and electrical connections.

The storage tank faucet is installed.

Optional Pump:

 Should not be plugged in until the storage tank is full.

Every 2 Weeks: 

Drain the boiling tank. 

CAUTION:

Storage tank will be very 

hot.  DO NOT TOUCH.

10

11

When Needed: 

Clean the Exterior. 

Fan Switch (ON)

Power Switch (ON)

Summary of Contents for 21598

Page 1: ...Operator s Manual Models 8G 10G 12G Pure Secure LLC 4511 NW 42nd St Lincoln NE 68524 USA Tel 402 467 9300 Toll Free in the USA 800 875 5915 Fax 402 467 9393 www MyAquaNui com TM ...

Page 2: ...talling the AquaNui Distiller 8 Connecting the Raw Water Line 9 Connecting the Power Cord 10 Start Up 10 Maintenance and Cleaning Overall Maintenance Requirements 11 Cleaning the Exterior 11 Draining the Boiling Tank 11 Cleaning the Boiling Tank 11 Changing the Pre Filter 12 Tank Sterilizing 13 Troubleshooting 14 AquaNui Distiller Parts List 16 AquaNui Distiller Exploded View 17 Storage Tank and P...

Page 3: ...distiller in water or any other liquid NEVER operate the distiller with a damaged cord or allow the cord to become exposed to hot surfaces DO NOT let children play with the distiller DO NOT touch the top of the distiller when it is operating because it may be hot Exercise care when removing the boiling tank and or the boiling tank lid Never remove boiling tank or lid when the distiller is operatin...

Page 4: ...below for future reference Date of Purchase Model Production Rate 8G 10G OR 12G Storage Tank Size Serial Number Included With Your Distiller In addition to your Pure Water AquaNui distiller the distiller box contains 1 4 compression nut 9550 15 of 1 4 food grade tubing 9526 15R VOC Pre lter 21048 Drain extension tube 518 Owners Manual Warranty Card Power Cord The AquaNui Storage Tank box contains ...

Page 5: ...ller Cooling Fan Power Cord Receptacle Power Fan Switches Raw Water Valve VOC Pre lter Overtemperature Reset Boiling Tank Drain Storage Tank 5 Gallon 10 Gallon or 15 Gallon Shown Distilled Water Spigot Pump Outlet Legs Adjustable Feet 5 ...

Page 6: ...ating element the low level microswitch is triggered causing feedwa ter to be added until the high level is reached If for some reason no water enters the boiling tank when needed the fan and heating element will turn off until the condition is corrected Once the storage tank is full of distilled water the unit will automatically shut down The AquaNui will begin distilling again once the water leve...

Page 7: ...esired location 3 Slide a leg onto the storage tank from the bottom Each leg is held on by 4 nuts on the bottom of the storage tank and 2 cap nuts on the side of the tank 4 Screw in the adjustable feet 5 Install the faucet with the gasket 6 Optional Pump Installation a If you have the optional pump install it at this time It is designed so that the end with the ttings extends to the rear of the st...

Page 8: ...nk need to be connected for the distilled water as well as the wire harness for the oats in the storage tank Second the fan blades were secured for shipment and must be released before the distiller is usesd 1 Remove the distiller from the packaging Use a phillips screwdriver to remove the back panel 2 Disconnect the water inlet and steam tubes to the boiling tank 3 Disconnect the two plastic part...

Page 9: ...handle before or during installation Be sure the piercing lance does not protrude beyond the rubber gasket Failure to do this may result in damage to the piercing needle Note The use of softened water for the raw water supply is recommended to minimize scale build up in the boiling tank and drain valve Note The Pure Water AquaNui comes standard with a saddle tapping valve In some areas a saddle ta...

Page 10: ...te the power cord in the parts kit bag Install the female end of the power cord into the outlet on the back of the unit Start Up Notes and Cautions Note This system must be fully grounded at all times The electrical receptacle you use must be a fully grounded single phase AC 115 120 volt 15 amp 220 VAC 7 5 amp minimum circuit If a two pronged wall receptacle is encountered it is the personal respo...

Page 11: ...on the water level in the storage tank Maintenance and Cleaning Overall Maintenance Requirements The following guide should be used for the maintenance of your distiller The timing will vary according to your local water conditions It is your responsibility to maintain your equipment Without proper maintenance your distiller may not produce optimum results The following is an average guide to main...

Page 12: ... Under no circumstances should the cleaning solution be heated and run through a steam sterilization or distillation cycle Note Failure to clean the boiling tank can result in scale build up causing prema ture heating element failure as well as reduced purity of the distilled water due to the possibilities of splash over of contaminants from the boiling tank To clean the boiling tank 1 Turn the Po...

Page 13: ...faucet to completely drain the storage tank 3 Make sure the main power switch is ON 2 Place a cup or small bucket under the storage tank faucet open faucet 3 Turn the fan switch to OFF This will start a Steam Sterilization cycle Steam will now be produced in the boiling tank The steam will pass through the coil but not be cooled The steam will heat up and sterilize the storage tank Allow the disti...

Page 14: ...ith water automatically Note Make sure the saddle tapping valve or utility hook up valve is turned ON to supply the feed water Note The water level in the storage tank must be below 3 4 full before the distiller will start If the oat ball inside the boiling tank is resting against the heat tab and is fully depressing the low level top microswitch you probably need to replace the micro switch Check...

Page 15: ...fan come on then you need to replace the relay Check with a volt ohm meter If the microswitch and relay check out ok then you may have a defective solenoid Turn the power switch to OFF If water continues to ow into the boiling tank then you need to replace the solenoid If the oat ball is heavy and has scale build up clean the boiling tank and if neces sary replace the oat If the oat is not moving ...

Page 16: ...PERATURE 1 4 20 63419 63419 63419 UNION BRASS 1 4 COMP USE DELRIN SLEEVES 21 9550 9550 9550 NUT COMP 1 4 PLASTIC 22 9019 9019 9019 SCREW 8 32 X 3 4 PHD PLPS 23 7197 7231 70106 VALVE SOL 1 4 COMP N C 24 21048 21048 21048 FILTER VOC AQUANUI PREFILTER 25 9541 9541 9541 TUBING 5 8 OD x 3 8 ID 26 9921 9921 9921 CLAMP HOSE WIRE SPRING 5 8 27 21007 02 21007 02 21007 02 PAN BOTTOM STUDDED 28 654 654 654 M...

Page 17: ...AquaNui Distiller Exploded Drawing 17 ...

Page 18: ...9592 LEG LEVELER DISPENSER 8 8014 8014 8014 FILTER AIR 80 MICRON HDPE 9 21025 21025 21025 PROBE ASSY MID AQUANUI 10 21021 21021 21021 PROBE ASSY HIGH AQUANUI 11 95315 95315 95315 FAUCET PLASTIC 3 8 NPT 12 144 144 144 WASHER RUBBER FOR MS FAUCET 13 221 0056 221 0056 221 0056 PLUG SPEEDFIT 3 8 STEM 14 9607 9607 9607 CONN SPEEDFIT 3 8 T X 3 8 M 15 21051 21051 21051 PUMP 120V AQUANUI WITH CORD 16 9614...

Page 19: ...Storage Tank and Pump Exploded Drawing Optional Pump Kit 19 ...

Page 20: ... 2013 Pure Secure LLC US and Foreign Patents Pending Form 21038 TM ...

Reviews: