Pure Link HTX-8800-U Owner'S Manual Download Page 21

PureLink by Dtrovision 

 

                                                                                                                                                                                                                 

21 

Router ID Error 

Indicates that the wrong ID number was entered 

 

Command Code Ack Value Examples 

Command Code 

Entered 

Ack Value as appears in the control 

program 

Explanation of Result 

*999CI01O01! 

 

*255sC I01O01 ! 

The command was successfully executed 

*999CO01! 

 

Command Code Error 

The command was not executed because 

the input number was not included 

*999CI01O01 

 

Command Code Error 

The command was not executed because “!” 

(End) was not included 

*300CI01O01! 

 

Router ID Error 

The command was not executed because 

the actual Router ID and entered Router ID 

did not match 

 

2.6   Connecting Switches 

A switch is an active connection between an input (source) signal and one or more output (display) 

devices. The signals connected in a switch command are either individual signals or groups of signals 

coming through the connectors on the rear of the unit.   

 

The “C” key initiates a Connect command for routing a switch. The characters and numbers that follow the “C” 

command tell the system, which inputs and outputs to connec

t. The last character “!” is found at the end of a 

command code which tells the system to execute the command. 

 

For example, the command code *999CI01O01! 

 

can be interpreted as follows: (*) Starting the command code (999) Router ID is 999 (C) Create connection on 

(I01) Input 01 to (O01) Output 01 (!) take the command. For a complete list of command characters and their 

functions, see examples below.   

 

To connect a switch: 

         

1. Enter the Connect command below. Replace the “#”s with the input and output number(s).   

              *999CI#O#! 

 

 

Examples (Connect) : 

Command Codes 

Action 

*999CI01O01! 

 

Connect Input 1 to Output 1 

*999CI01O04,I04O02! 

 

Connect Input 1 to Output 4 and Input 4 to Output 2 

*999CI01O01,I02O02,I03O03! 

 

Connect Input 1 to Output 1, Input 2 to Output 2, and Input 3 to Output 3 

*999CI01O01,02,03! 

 

Connect Input 1 to Output 1, 2, and 3 

Summary of Contents for HTX-8800-U

Page 1: ...h POE and HDCP 2 2 PureLinkTM 535 East Crescent Avenue Ramsey NJ 07446 USA Tel 1 201 488 3232 Fax 1 201 621 6118 E mail sales purelinkav com www purelinkav com For order support please contact your lo...

Page 2: ...ontrol 13 1 12 Cable Termination 14 1 13 Installation Guidelines 17 1 14 Communication Settings 17 Chapter 2 Communication Code Configuration 2 1 Control Programmer s Guide 18 2 2 Overview 18 2 3 Comm...

Page 3: ...hen operating this unit This unit may be equipped with a 3 wire grounding type plug a plug having a third grounding pin This pin will only fit in to a grounding type power outlet If you are unable to...

Page 4: ...pment Safety and or CPU Boards and Power Supplies used Council Directive 93 68 EEC with Matrix Dtrovision LLC 535 E Crescent Ave Ramsey NJ 07446 201 488 3232 declares under sole responsibility that th...

Page 5: ...or local destinations such as in room displays AVRs and switchers Audio de embedding for each output via 1 3 5mm analog stereo or 1 RCA coaxial digital output Auto EDID management EDID library and EDI...

Page 6: ...Panel Figure 1 1 POWER Main power switch ON OFF DISPLAY View menu and system mode MENU EDID setup menu UP Up button DOWN Down button ENTER Execution button 1 6 Front panel button operation Creating a...

Page 7: ...play will result in no image on the display EDID handshake may sound simple however with multiple peripheral devices within the chain display s EDID information easily get lost or blocked while it is...

Page 8: ...recommended to use scaling option 1 7 Rear View of HTX 8800 U Back Panel Figure 1 2 IR EXT IN OUT IR ext is for HTX 8800 U control IR Inputs and IR outputs are for IR communication on HDBT outputs pa...

Page 9: ...IN Receives HDBaseT signal from HTX series matrix switcher s HDBaseT output There are LED signal status indicators next HDMI output port and HDBaseT input port HTX RX S Scaling receiver Scaling recei...

Page 10: ...al from HTX series matrix switcher s HDBaseT output MODE SELECT To select scaling mode between Upscaling Downscaling and Bypass Upscaling mode signal process Input signal Output signal 1080p 24Hz 4K 2...

Page 11: ...2 2 EDID RS 232 2 way device control and monitoring Fixed baud rate at 115200 8 data bits no parity and 2 stop bits LAN TCP IP Default IP 192 168 0 100 Video Switcher HDMI input HDBaseT HDMI output 8x...

Page 12: ...wer supply optional Operational Temperature 32 117 F 0 to 47 C Storage Temperature 4 140 F 20 to 60 C Humidity 0 90 non condensing MTBF 50 000 hours Dimensions W x D x H 4 0 x 4 0 x 0 9 102 x 102 x 22...

Page 13: ...for HTX 8800 U control IR INPUT These ports are for IR communication of end points via HTR Rx HDBaseT receiver 1 8 indicate each HDBaseT output Connect IR blasters to the IR inputs IR OUTPUT These por...

Page 14: ...device the sensor should be able to be seen through the plastic as a small round object inside Insert 3 5mm jacks of IR RX receivers into RX ports making sure the receivers themselves are placed in c...

Page 15: ...ort purelinkav com CX SERIES TOTALWIRE CAT X High Performance Cable CX 010 Certified CATx Cable with TotalWire Technology 10m CX 020 Certified CATx Cable with TotalWire Technology 20m CX 030 Certified...

Page 16: ...ed 9 Not used LAN Cable Termination for Control The following table shows the pinout of the LAN connector Note that in the pinout table some transmit receive functions abbreviated as Tx Rx are differe...

Page 17: ...onal humidity should be 60 or below Operational environment should be dust free and well ventilated Stabilized AC input power AVR based power supply is highly advised 1 14 Communication Settings LAN a...

Page 18: ...and Code Formats A command code is a series of command characters and numbers used to send commands to the system Commands include basic formulas for creating and disconnecting switches as well as for...

Page 19: ...egin with Start byte All s end with End byte All s will be executed when Enter is entered The correct Router ID must be entered in a command code Systems will not react to the command if a wrong Route...

Page 20: ...rsion check Firmware version check command 255 version 2 5 Command Ack Acknowledge Value Response When command codes are entered into a terminal emulation program such as HyperTerminal and are accepte...

Page 21: ...coming through the connectors on the rear of the unit The C key initiates a Connect command for routing a switch The characters and numbers that follow the C command tell the system which inputs and o...

Page 22: ...O00 Output 00 take the command For a complete list of command characters and their functions see the command list below 1 Enter the Disconnect command below Replace the s with the input and output num...

Page 23: ...ower off 999poweroff Factory setting restore 999restore Reboot 999reboot 2 8 Status Check A connection status can be checked to confirm that the switch has been correctly executed or to confirm correc...

Page 24: ...24 999 O04 Check Input connection status on Output 4 999 ALLIO Check all Input and Output connection status Input EDID status 999 EDIDi01 I01 input 1 i02 input 2 i03 input 3 i04 input 4 Firmware vers...

Page 25: ...UI Guide Google Chrome is recommended for web UI HTX web UI consists with five menus 1 General 2 Control 3 EDID 4 Status 5 Upgrade 1 General Input output connection status check Matrix power control M...

Page 26: ...PureLink by Dtrovision 26 2 Control Intuitive X Y switching 3 EDID Internal EDID library External EDID emulation EDID merge Current EDID status check...

Page 27: ...nk by Dtrovision 27 4 Status Network configuration status Video signal status for inputs and outputs Audio signal status for inputs and outputs HDCP status for inputs and outputs 5 Upgrade Firmware up...

Page 28: ...part to replace the defective item 3 Refund to customer the purchase price paid for the defective product All products that are replaced become the property of PureLink Replacement products may be ne...

Reviews: