LIMITED ONE YEAR WARRANTY

 

 

This PUR product is warranted to the original owner to be free from electrical and mechanical defects in material and 

workmanship, under normal use and maintenance, within its listed capacity, for a period of one (1) year from the date 

of original purchase; except however, for the prefilters or ionizing wires, which may have to be replaced from time to 

time.  This PUR product must not have been moved from the site of original installation.  A new or remanufactured part 

to  replace  the  defective  part  will  be  provided  without  charge  for  the  part  itself,  through  PUR  DISTRIBUTION  or  an 

authorized PUR DISTRIBUTION service dealer, provided the defective part is returned to PUR DISTRIBUTION or the 

PUR  DISTRIBUTION  service  dealer 

prepaid

,  together  with  the 

serial  number,  date  of  installation,  and  proof  of 

purchase

.  Defective parts must be packaged well and depending on the part, may require images emailed to PUR 

DISTRIBUTION prior to shipping, to confirm condition of parts.  If goods arrive damaged due to improper packaging, 

warranty  will  be  void.    The  replacement  part  assumes  the  unused  portion  of  the  warranty.    Failing  this,  PUR 

DISTRIBUTION will guarantee the unit for a period of twelve (12) months from the date of manufacture, according to 

the manufacturer’s records. 

 

THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS

 incurred 

for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement 

parts.  Such costs may be covered by a separate warranty provided by the dealer. 

 

LIMITATIONS  OF  WARRANTY 

- All implied warranties (including implied warranties of merchantability) are hereby 

limited  in  duration  to  the  period  for  which  the  limited  warranty  is  given.    The  expressed  warranties  made  in  this 

warranty  are  exclusive  and  may  not  be  altered,  enlarged,  or  changed  by  any  distributor,  dealer  or  other  person 

whatsoever. 

 

PUR DISTRIBUTION LTD. will not be responsible for: 

1.  Normal  maintenance  as  outlined  in  the  Operation  &  Maintenance  Manual  including  cleaning  of  electronic 

collecting cells and/or replacement of prefilters. 

2.  Damage or repairs required as a consequence of faulty installation or application by others. 

3.  Damage or repairs needed as a consequence of any misapplication, negligent handling, improper servicing, 

unauthorized alteration, or improper operations. 

4.  Failure  to  start  due  to  voltage  conditions,  blown  fuses,  open  circuit  breakers  or  other  damages  due  to  the 

inadequacy or interruption of electrical service. 

5.  Damage  as  a  result  of  floods,  winds,  fires,  lightning,  accidents,  corrosive  atmosphere,  or  other  conditions 

beyond the control of PUR DISTRIBUTION LTD. 

6.  Parts not supplied or designated by PUR DISTRIBUTION LTD. 

7.  PUR DISTRIBUTION LTD. products installed outside the continental Canada, U.S.A., Alaska, and Hawaii. 

8.  Any  personal  injury,  special  indirect  or  consequential  property  or  commercial  damage  of  any  nature 

whatsoever. 

 

Model No. 

 

 

 

 

 

Serial No. 

 

Date of Purchase 

 

 

 

 

Dealer Name 

 

Owner’s Company Name & Address 

 

RETAIN THIS CERTIFICATE WITH YOUR VALUABLE DOCUMENTS 

PUR DISTRIBUTION LTD. 

Tel:  (416) 410-3450 

[email protected]      www.purdistribution.com 

Summary of Contents for SSCB15G-R

Page 1: ...MODELS SSCB15W R SSCB15W RE SSCB15G R SSCB15G RE CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL 416 410 3...

Page 2: ...d spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employ...

Page 3: ...ALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable t...

Page 4: ...tine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX...

Page 5: ...cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indi...

Page 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt...

Page 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt...

Page 8: ...Ionizing Wire R8 0443 10 Safety Interlock Switch C5 0202 11 Red Indicator Light C5 0113 12 Power Switch Gray C5 0222 Description Part Number 12a Power Switch Black C5 0221 13 3 Position Slide Switch G...

Page 9: ...ve parts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are...