background image

MAJOR COMPONENTS 

Description 

The Electronic Air Cleaner is approximately 29½ x 27 x 

14½ inches (75 x 68.6 x 37 cm).  The unit is designed 

to  be  mounted  to  the  ceiling.    The  steel  cover  and 

intake  grill  are  hinged  to  allow  easy  access  to  the 

Collecting Cells and Power Box.  The unit is rated up to 

1300 CFM (2210 m

3

/hr). 

Cabinet 

The  cabinet  is  constructed  of  20  gauge  steel.    The 

external  parts  have  a  tough  powder-coated,  scratch-

resistant finish.  The internal parts are galvanized steel.  

Access  to  the  Collecting  Cells,  Power  Box  and 

Prefilters  is  made  by  lifting  the  cover,  sliding  towards 

the front and lowering. 
The cover is interlocked to cut power to the unit when 

opened. 

Prefilters

 

The  washable  Prefilters  measuring  12½  x  20  inches 

(31.75  x  50.8  cm)  are  constructed  of  multi-layers  of 

aluminum  mesh  for  maximum  filtration  of  large 

particles. 

Collecting Cells

 

The  dual  voltage  Collecting  Cells  are  constructed  of 

heavy gauge aluminum to resist rust and damage.  The 

first  stage,  the  ionizing  section,  is  charged  at 

approximately  7500  VDC.    The  collecting  plates  are 

alternately  grounded  and  charged  at  5000  VDC.    The 

arrow  on  the  Cell  indicates  the  direction  of  air  flow 

which must point up towards the fan motor. 

 

 

 

 

 

Motor & Fan Blade

 

The motor is 1/12 HP, 1050 RPM, 3 speed, controlled 

by  a  3-position  slide  switch.    The  motor  is  thermally 

protected.  The fan blade is aluminum, 18 inches (45.7 

cm) with a 16˚ pitch. 

INSTALLATION 

1.  Read  instructions  carefully.    Failure  to  do  so  may 

result in product damage or injury. 

2.  Make sure the sizing is correct for your application. 

3.  Installation  should  be  done  by  a  knowledgeable 

technician. 

4.  After  installation,  check  out  operation  as  provided 

in these instructions. 

Mounting 

1.  Remove the unit from the box with packing still on 

the unit and lay it on its back, grill side up. 

2.  Release  the  cover  by  sliding  towards  the  front  of 

the unit and lifting up. 

3.  Remove  the  "S"  hook  from  each  chain,  tilt  cover 

up, and release from back. 

4.  Holes are provided in the cabinet to accommodate 

5/16 inch (8 mm) threaded rod.  Threaded rod can 

be  attached  to  angle  iron,  laid  across  the  joists, 

and  drilling  holes  through  these  supports.    Pass 

threaded  rod  up  through  the  supports  and  secure 

with  two  nuts  and  washers.    This  will  allow 

adjustment  of  the  unit  so  that  it  is  flush  with  the 

underside of the ceiling. 

 

Leave enough room around the Air Cleaner for 

removal of Collecting Cells and Prefilters.

 

5.  Replace cover and chain. 

Blower  and  Motor  are 

hidden  behind  4  directional 

discharge air grills. 

 

 

 

Rear  Hinges  permit  smooth 

release  of  cover  for  easy 

installation. 

 

 

 

3-Speed  Fan  Control  allows 

adjustment  of  air  flow  to 

activity level in room. 

 

 

Hinged 

Cover 

provides 

convenient  access  to  Grill, 

Prefilters  and  Collecting 

Cells.  Safety  interlock  cuts 

power 

when 

cover 

is 

opened. 

Heavy  duty  Collecting  Cells 

(2) 

capture 

airborne 

pollutants  and  simply  wash 

clean. 

 

 

 

 

Washable,  aluminum  mesh 

Prefilters  (2)  catch  lint  and 

large  particles  before  they 

enter collecting cells. 

 

 

 

 

Removable  Intake  Grill  for 

easy cleaning. 

 

Summary of Contents for SSCB15G-R

Page 1: ...MODELS SSCB15W R SSCB15W RE SSCB15G R SSCB15G RE CEILING MOUNTED ELECTRONIC AIR CLEANER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT FOR TECHNICAL SUPPORT AND REPLACEMENT FILTERS CALL 416 410 3...

Page 2: ...d spores fungi bacteria viruses and more down to 0 01 micron 0 01 micron 1 2 540 000 of an inch BENEFITS Helps clear up a smokey environment quickly so customers can dine more comfortably Helps employ...

Page 3: ...ALLATION 1 Read instructions carefully Failure to do so may result in product damage or injury 2 Make sure the sizing is correct for your application 3 Installation should be done by a knowledgeable t...

Page 4: ...tine remains on plates let Cells soak in hot soapy water for 30 minutes Never use any instrument to clean the cell as this may damage the ionizing wires or bend cell plates 5 Spray Prefilters with DAX...

Page 5: ...cover is completely closed and locked into place 4 Power switch is ON Performance Indicator Light Is Not Lit 1 System switch is ON 2 Remove Cells close access door and turn unit ON If Performance Indi...

Page 6: ...Electrical Schematic B with Wired Remote 120 Volt Electrical Schematic A 120 Volt...

Page 7: ...Electrical Schematic B with Wired Remote 220 240 Volt Electrical Schematic A 220 240 Volt...

Page 8: ...Ionizing Wire R8 0443 10 Safety Interlock Switch C5 0202 11 Red Indicator Light C5 0113 12 Power Switch Gray C5 0222 Description Part Number 12a Power Switch Black C5 0221 13 3 Position Slide Switch G...

Page 9: ...ve parts or replacement parts Such costs may be covered by a separate warranty provided by the dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are...

Reviews: