* NSF/ANSI 55 class B maximum rated flow
System tested and certified by NSF International against NSF/ANSI Standard 55 and CSA B483.1 for disinfection performance, class B.
Specifications:
NSF/ANSI Standard 55 Class B and CSA B483.1
Model Number:
PUV15S
PUV25S
PUV15H
PUV25H
Flow Rate GPM US (LPM)*
7.4 (28.2)
12.3 (46.6)
15.5 (58.7)
25.6 (96.9)
Dimensions
Controller
8" x 2" x 3"( 20.3cm x 5.1cm x 7.6cm)
Chamber Diameter
3.5” (8.9 cm)
3.5” (8.9 cm)
3.5” (8.9 cm)
3.5” (8.9 cm)
Chamber Length
18.5" (47 cm)
28" (71.1 cm)
18.5" (47 cm)
28" (71.1 cm)
I/O Port Size
3/4” FNPT - 1.0” MNPT
System Operating Pressure
15-125psi (103-862kPa)
Electrical
Voltage
100-240, 50/60Hz
Power Consumption (W)
21
35
46
67
Lamp Watts (W)
17
30
40
60
Chamber Material
304SS
About Your System:
Conditions for Operation:
Water quality will impact the performance of your UV system, and the following levels should be utilized as a guideline for pre-
treatment requirements of the influent water supply prior to UV treatment:
If you are using untreated surface water or untreated groundwater as your source of supply, the suitability of the water supply for
potable applications must be confirmed by the provincial/state and/or local health agency that has jurisdiction.
If the test results indicate that: (1) any of the above contaminant levels are being exceeded, or (2) any prevailing drinking water
health standards are not being met, additional pre-treatment options must be installed that will eliminate all contaminants
posing health risks. Non-municipal water should be tested on an ongoing basis to ensure treatment efficiency.
Iron................................................. < 0.3 ppm (0.3 mg/L)
Turbidity ......................................... < than 1 NTU
Tannins .......................................... < 0.1 ppm (0.1 mg/L)
Manganese..................................... < 0.05 ppm (0.05mg/L)
Hardness ........................................ < 120 ppm (7 grains per gallon)
UV Transmittance ........................... > 75%
Installation Instructions:
Install your UV system in a location that provides ample space for accessing and removing the lamp and quartz sleeve from the UV
chamber. A minimum distance equivalent to the length of the UV reaction chamber (stainless steel cylinder) plus 6-12” (15-30cm)
is required to ensure adequate clearance. As the UV system generates heat during use, ensure that no combustible items come into
contact with, or are in proximity to the system. It is recommended that you maintain at least 6” (15 cm) of clear wall space on all
sides of the UV for cooling purposes. This will prolong the operating life of the system. Mount electronic controllers where they will
not get wet during maintenance or from condensation from copper pipes, etc.
Accessibility, Orientation & Fittings: