Performance Data Sheet
For Pitchers Model No. CR-1100C, PPT700W. Dispenser Model No. DS-1800Z.
Replacement Filter Model No. CRF950Z (Included with system) and PPF951K (Sold seperately) These systems have been
tested according to NSF/ANSI 42, 53 and 401 for reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42, 53 and 401.
Substance
Cadmium (pH6.5)
0.03 ±10%
Copper (pH8.5)
3.0 ± 10%
Cadmium (pH8.5)
0.03 ±10%
2,4-D
0.210 ± 10%
10 mg/L ± 10%
Mercury (pH6.5)
0.006 ± 10%
Nominal Particulate (Class I)
(Class I, particles 0.5 to <1µm)
at least 10,000 particles/mL
Atrazine
0.009 ± 10%
Mercury (pH8.5)
0.006 ± 10%
0.015 ± 10%
0.015 ± 10%
Zinc
minimum 50,000/L
Copper (pH6.5)
3.0 ± 10%
Benzene
0.015 ± 10%
Influent challenge
concentratio n( mg/L)
% Reductio n Requirement /
Maximum permissible product
water concentratio n (mg/ L)
Table 1.3 NSF/ANSI Standard 53 - Health Effects NSF Certified
Cyst
5 mg/L
85%
0.005
1.3
0.005
0.07
0.002
0.003
0.002
0.005
0.005
0.9995%
1.3
0.005
Tetrachloroethylene
Carbon Tetrachloride
Performance
Data Sheet
NSF/ANSI Standard Requirement s
PUR Reduction Data
Chlorine (Taste & Odour)
2.0 mg/L ± 10%
0.15 ± 10%
0.15 ± 10%
Table 1.2 NSF/ANSI Standard 42 - Aesthetic Effects NSF Certified
Table 1.1 Standard 53 - certified by WQA to the NSF/ANSI Standard
Lead (pH8.5)
50%
0.01
0.01
Lead (pH6.5)
Overall %
Reductio n
98.3%
95.1%
98.7%
86.0%
86.9%
96.7%
>99.9%
82.7%
>96.6%
>96.6%
96.0%
99.99%
98.2%
>96.4%
>97.5%
97.8%
99.4%
PPF951K
Certified with system,
sold seperately.
Overall %
Reductio n
98.3%
95.1%
98.7%
86.0%
86.9%
96.7%
99.1%
82.7%
>96.6%
>96.6%
96.0%
98.2%
>99.99%
>96.4%
>97.5%
Not Certified
Not Certified
CRF950Z
Included with system