VII. Maintenance and Care 

 

1.  During  prolonged  operation  of  the  RO  system,  fine  sediments  and 

bacteria may settle on the membrane surface and block the flow. It 

is therefore advisable to carry out a regular rinse: 

 

a.  Manual flushing

 

b.  Rinsing procedure: Open the inlet water valve and allow the device 

to rinse for approx. 5 - 10 minutes. Then close the inlet water valve 

again. 

 

2.  To ensure an excellent quality of ultrapure water, the filters must be 

replaced regularly. The lifetime of each filter varies depending on the 

quality of the input water. A family of three has on average a daily 

water consumption of about 10 liters of drinking water. The filters 

should therefore be replaced as follows: 

 

 

 

Stage 1 - PP filter 10 microns: about 3 - 6 months 

Stage 2 - GAC granular activated carbon filter: approx. 3 - 6 months 

Stage 3 - CTO activated carbon block 5 microns: about 3 - 6 months 

Stage 4 - UF fine filter 0.02 micron: approx. 6 - 12 months 

Stage 5 - RO membrane: approx. 12 - 24 months 

Level 6 - T33 post activated carbon filter: approx. 6 - 12 months 

Stage 7 - mineralization filter: approx. 6 - 12 months 

 

 

 

 

 

A change of filters is necessary if the following situations occur: 

 

1.  The  quality  of  the  ultrapure  water  deteriorates  and  the  taste 

changes 

2.  The ultrapure water volume decreases noticeably. (ATTENTION: a 

reduced  volume  of  ultrapure  water  production  also  results  from  a 

change in the temperature of the input water.) 

Attention! 

1.  We recommend having the installation carried out by a specialist, 

as a drill and other power tools are used during assembly. If you 

install the reverse osmosis system yourself, please follow exactly 

the listed individual steps. Please keep children away from the 

device. 

2.  When drilling, make sure that there are no water and electrical 

cables behind it. The device must be connected to a grounded 

power outlet. The power adapter must be stored in a 

well-ventilated and watertight location. 

 

 

If any of the following occurs, disconnect the unit immediately from 

the  water  supply  (close  the  inlet  water  ball  valve)  or  disconnect  the 

power cord and repair: 

 

- if water comes out of the water pipes or other components 

- if some of the elements are not working properly 

- if some components carry electricity 

- if you notice other anomalies or errors on the device 

 

 

 

 

Summary of Contents for BOOSTER QUICK 7 Steps -400 GPD

Page 1: ...water hose 6mm 9mm 3 1 x user manual 4 1 x faucet incl connection material Attention The RO membrane is packed separately and must be inserted into the membrane housing before first use III Introduction to the main functions of the reverse osmosis system 1 1st stage PP 10 micron filter for filtration of coarser sediments such as rust sand dust etc 2 2nd stage GAC activated carbon filter for filter...

Page 2: ...coarse to very fine contaminants colloids organic pollutants heavy metals dissolved solids bacteria and viruses etc while maintaining the same molecular structure of water and dissolved oxygen The achieved reduction rate can be up to 96 ensure a stable environment for the RO membrane automatically at a lower water pressure of 0 5 BAR or when the water supply is blocked ch to prevent overheating of...

Page 3: ...s activating the inner circlip B Installation of reverse osmosis system 1 Close the inlet valve and unscrew the metal hose Take the supplied 3 way socket and connect one end to the water outlet valve Screw the other end of the unscrewed metal hose to the 3 way sleeve with the nut 1 Take the supplied water inlet ball valve and wrap one end with Teflon tape Spray the valve with some silicone spray a...

Page 4: ...ons for leaks Connect the device to the power supply to put it into operation At the beginning it is possible that the water is a bit dark and some carbon dust can escape from the carbon block This is absolutely harmless and the water will be clear after a few minutes 3 Close the faucet and check that the unit shuts off and the solenoid valve stops the water inlet Then open the faucet and check if...

Page 5: ... If the device is in operation for too long the OVERHAUL indicator lights up and the device shuts off Switch off the power wait a moment and switch the device on again Check if a filter or membrane change is necessary Terms of use 1 To prevent microbial contamination on the membrane components during storage and transportation the membrane was coated with a light protective solution and the post a...

Page 6: ... Stage 7 mineralization filter approx 6 12 months A change of filters is necessary if the following situations occur 1 The quality of the ultrapure water deteriorates and the taste changes 2 The ultrapure water volume decreases noticeably ATTENTION a reduced volume of ultrapure water production also results from a change in the temperature of the input water Attention 1 We recommend having the ins...

Page 7: ...ve created for the return of old equipment can be obtained via the following link Return of old equipment 2 Disposal note Please remove the filter cartridges from the reverse osmosis system and dispose them of in the household waste before adding the rest of the system to electrical scrap 3 We would like to point out to all owners of electrical and electronic waste equipment that they are legally ...

Page 8: ...PUR BOOSTER QUICK 7 Steps 400 GPD REVERSE OSMOSIS SYSTEM ...

Reviews: