1.  Drill  a  6  mm  hole  in  the  basin  drainpipe.  Cut  the  supplied  6  mm 

hose with scissors to the desired length and insert one end into the 

drilled hole. Seal the hole with silicone gel. Attach the drain hose to 

the drain pipe with a cable tie or hose clamp. 

 

 

 

 

 

 

 

 

 

 

 

         

   

                                               

 

 

1.  Drill a 12mm hole through the sink where you want to attach the faucet. 

Take the supplied faucet, place the stainless steel neck on the faucet 

body, lower the faucet into the provided hole, place a washer on it from 

underneath and screw the faucet tightly with the nut. Take the supplied 

6  mm  hose  and  cut  it  with  scissors  to  the  desired  length.  Press  the 

supplied 6 mm plug into the end of the hose and fasten it with the nut 

on the water inlet. 

2.  Open the faucet and fill the device with water. Check all connections for 

leaks. Connect the device to the power supply to put it into operation. 

At  the  beginning  it  is  possible  that  the  water  is  a  bit  dark  and  some 

carbon  dust  can  escape  from  the  carbon  block.  This  is  absolutely 

harmless and the water will be clear after a few minutes. 

3.  Close  the  faucet  and  check  that  the  unit  shuts  off  and  the  solenoid 

valve stops the water inlet. Then open the faucet and check if the unit 

turns on and the high pressure switch is reset. 

 

4.  Installation of reverse osmosis membrane 

 

Unscrew  the  inlet  water  connection  of  the  membrane  cover.  Remove  the 

hose  and  use  the  membrane  spanner  to  loosen  the  membrane  cover. 

Unpack  the  membrane  and  press  the  end  with  the  O-ring  first  into  the 

membrane  shell.  Tighten  the  membrane  cover  and  secure  it  with  the 

membrane  spanner.  Insert  the  water  inlet  hose  back  into  the  water  inlet 

connection oft he membrane cover, secure it and place the membrane shell 

in the provided holder of the reverse osmosis system. 

Summary of Contents for BOOSTER QUICK 7 Steps -400 GPD

Page 1: ...water hose 6mm 9mm 3 1 x user manual 4 1 x faucet incl connection material Attention The RO membrane is packed separately and must be inserted into the membrane housing before first use III Introduction to the main functions of the reverse osmosis system 1 1st stage PP 10 micron filter for filtration of coarser sediments such as rust sand dust etc 2 2nd stage GAC activated carbon filter for filter...

Page 2: ...coarse to very fine contaminants colloids organic pollutants heavy metals dissolved solids bacteria and viruses etc while maintaining the same molecular structure of water and dissolved oxygen The achieved reduction rate can be up to 96 ensure a stable environment for the RO membrane automatically at a lower water pressure of 0 5 BAR or when the water supply is blocked ch to prevent overheating of...

Page 3: ...s activating the inner circlip B Installation of reverse osmosis system 1 Close the inlet valve and unscrew the metal hose Take the supplied 3 way socket and connect one end to the water outlet valve Screw the other end of the unscrewed metal hose to the 3 way sleeve with the nut 1 Take the supplied water inlet ball valve and wrap one end with Teflon tape Spray the valve with some silicone spray a...

Page 4: ...ons for leaks Connect the device to the power supply to put it into operation At the beginning it is possible that the water is a bit dark and some carbon dust can escape from the carbon block This is absolutely harmless and the water will be clear after a few minutes 3 Close the faucet and check that the unit shuts off and the solenoid valve stops the water inlet Then open the faucet and check if...

Page 5: ... If the device is in operation for too long the OVERHAUL indicator lights up and the device shuts off Switch off the power wait a moment and switch the device on again Check if a filter or membrane change is necessary Terms of use 1 To prevent microbial contamination on the membrane components during storage and transportation the membrane was coated with a light protective solution and the post a...

Page 6: ... Stage 7 mineralization filter approx 6 12 months A change of filters is necessary if the following situations occur 1 The quality of the ultrapure water deteriorates and the taste changes 2 The ultrapure water volume decreases noticeably ATTENTION a reduced volume of ultrapure water production also results from a change in the temperature of the input water Attention 1 We recommend having the ins...

Page 7: ...ve created for the return of old equipment can be obtained via the following link Return of old equipment 2 Disposal note Please remove the filter cartridges from the reverse osmosis system and dispose them of in the household waste before adding the rest of the system to electrical scrap 3 We would like to point out to all owners of electrical and electronic waste equipment that they are legally ...

Page 8: ...PUR BOOSTER QUICK 7 Steps 400 GPD REVERSE OSMOSIS SYSTEM ...

Reviews: