INSTALLATION & INITIAL STARTUP 

(CONTINUED)

IMPORTANT SAFETY WARNINGS

CONNECT TO MODEM AND ROUTER

Plug in your modem and wireless router into the receptacles on the rear panel of the UPS. Push the power 

button on the front of the unit.  Connected devices will now be protected by the UPS.

POWERING THE  UPS

Turn on the UPS unit by pressing the power button on the front. Turn off the UPS unit by pressing the power 

button again.

COLD START FUNCTION

If the UPS is off and not connected to power, it’s still possible to cold start the UPS to power connected 
devices if the battery has sufficient charge. 

CAUTION!   NEVER connect a laser printer or scanner to the UPS unit. This may cause 

damage to the unit.

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY 

OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING WARNINGS:

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area 

free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)

CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the 

unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.

CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave 

ovens, irons, or vacuum cleaners to UPS.

CAUTION! Do not plug the UPS input into its own output.

CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-

containing vessels on or near the unit.

CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power 

supply to properly disable the UPS.

CAUTION! Do not attach a power strip or surge suppressor to the UPS.

CAUTION! Hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage 

still may be accessible through supply from battery. The battery supply should therefore be disconnected in the plus 

minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.

CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and 

the required precautions. Keep unauthorized personnel away from batteries.

CAUTION! When replacing the batteries, use the same number and type of batteries.

CAUTION! Internal battery voltage is I2VDC. Sealed, lead-acid, 6-cell battery.

CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or 

batteries. Released electrolyte is harmful to the skin and eyes.

CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.

CAUTION! A battery can present a risk of electric shock and high short circuit current. 

Summary of Contents for PS2000UG

Page 1: ...ury or death INSTALLATION AND OPERATING INSTRUCTIONS System Solid State Pump Controller Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000UG The PumpSpy System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or hi...

Page 2: ...e connected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connec...

Page 3: ...he WiFi controller 6 Plug the WiFI controller into AC power TEST THE SYSTEM IN THIS ORDER IT S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL PLUMBING FOR LEAKS DURING TESTING Lift the lowest Battery Backup switch and hold Release when the battery backup pump cycles The BACKUP PUMP status LED will remain GREEN The MAIN PUMP status LED will turn RED and the alarm will sound Press ALARM ...

Page 4: ...ontroller Yellow Blinking Red Red Red Green Alternating MAIN PUMP No Cycle Recorded Main Pump Fail Backup Pump Activated High Amp Draw Jammed Pump Excessive Run Time BACKUP PUMP No Cycle Recorded Backup Pump Fail High Amp Draw Jammed Pump Excessive Run Time WATER LEVEL High Water Alert POWER AC Outage No Battery Reverse Polarity BATTERY Low Battery 25 Charge Critical Battery 10 Charge No Battery R...

Page 5: ...lace the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations CONNECTTO AC POWERTO BEGIN BATTERY CHARGING Plug in the AC input cord to the wall outlet For the best results charge the battery at least 6 hours before initial use The unit charges its battery wh...

Page 6: ...ent life support equipment microwave ovens irons or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to prope...

Page 7: ... is short The UPS is overloaded Remove some devices BatteryVoltage is too low Charge the UPS at least 6 hours Battery Defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery LED is flashing but no apparent issue Reconnect the power cord properly Reconnect the power cord properly TROUBLESHOOTING WARNING Alwa...

Page 8: ...ransportation or house calls However if you mail your product to PumpSpy for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed unde...

Reviews: