INSTALLATION AND OPERATING INSTRUCTIONS

System Solid State Pump Controller

Power Supply Requirements  

 120 VAC, 60 Hz, 

15 AMP

Electrical Ratings 

 

12Amps @ 120 VAC; 
18 Amps @ 12 VDC

Relative Humidity 

0 to 80%

Storage Temperature 

0° to 70°C

Operating Temperature 

0° to 50°C

SPECIFICATIONS

PumpSpy

 PS2000UG

The PumpSpy System requires a 12V Deep Cycle Battery (not included), 40 amp/hr 

minimum, 75 amp/hr or higher recommended. SLA/AGM Battery strongly recommended.

CELLULAR CONVERSION KIT

24/7 AUTOMATED REMOTE SUMP PUMP MONITORING

Summary of Contents for PS2000UG

Page 1: ...ury or death INSTALLATION AND OPERATING INSTRUCTIONS System Solid State Pump Controller Power Supply Requirements 120VAC 60 Hz 15 AMP Electrical Ratings 12Amps 120VAC 18 Amps 12VDC Relative Humidity 0 to 80 Storage Temperature 0 to 70 C Operating Temperature 0 to 50 C SPECIFICATIONS PumpSpy PS2000UG The PumpSpy System requires a 12V Deep Cycle Battery not included 40 amp hr minimum 75 amp hr or hi...

Page 2: ...e connected power cords with wet hands WARNING The PumpSpy System has not been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connec...

Page 3: ...he WiFi controller 6 Plug the WiFI controller into AC power TEST THE SYSTEM IN THIS ORDER IT S RECOMMENDED TO RUN INITIAL CYCLES WITH WATER AND CHECK ALL PLUMBING FOR LEAKS DURING TESTING Lift the lowest Battery Backup switch and hold Release when the battery backup pump cycles The BACKUP PUMP status LED will remain GREEN The MAIN PUMP status LED will turn RED and the alarm will sound Press ALARM ...

Page 4: ...ontroller Yellow Blinking Red Red Red Green Alternating MAIN PUMP No Cycle Recorded Main Pump Fail Backup Pump Activated High Amp Draw Jammed Pump Excessive Run Time BACKUP PUMP No Cycle Recorded Backup Pump Fail High Amp Draw Jammed Pump Excessive Run Time WATER LEVEL High Water Alert POWER AC Outage No Battery Reverse Polarity BATTERY Low Battery 25 Charge Critical Battery 10 Charge No Battery R...

Page 5: ...lace the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations CONNECTTO AC POWERTO BEGIN BATTERY CHARGING Plug in the AC input cord to the wall outlet For the best results charge the battery at least 6 hours before initial use The unit charges its battery wh...

Page 6: ...ent life support equipment microwave ovens irons or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to prope...

Page 7: ... is short The UPS is overloaded Remove some devices BatteryVoltage is too low Charge the UPS at least 6 hours Battery Defect It might be due to high temperature operation environment or improper operation to battery Replace the battery with the same type of battery LED is flashing but no apparent issue Reconnect the power cord properly Reconnect the power cord properly TROUBLESHOOTING WARNING Alwa...

Page 8: ...ransportation or house calls However if you mail your product to PumpSpy for warranty service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed unde...