background image

 

 

 
 

       

3. Indication of the device operation 
 

3.1 LED indication of operating status 

The PSU is equipped with two diodes on the front panel: 

 

 
RED LED: 

 

on – the PSU is supplied with 230 V   

 

off – no 230 V supply 

 

GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

 

 

3.2 Optical indication of the switch operation (see Table 8). 

 

Table 8. Indication of the switch operation 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

 

GREEN LED LIGHT (Power) 
Indication of the switch's 
power supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION AT THE PoE PORTS (1

÷4) 

 

GREEN LED LIGHT (PoE) 
Indication of the PoE power 
supply at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant with 

the IEEE802.3af standard) 

ON

 

– supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10MB/s or 100Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UP LINK PORTS 

 

GREEN LED LIGHT 

 

 

OFF

- no connection/ the device is connected 10Mb/s 

ON 

– the device is connected 100Mb/s 

YELLOW LED LIGHT (LINK) 
The connection status of 
LAN devices, 10MB/s or 
100Mb/s  and data 
transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected: 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

Summary of Contents for S64-B

Page 1: ...lor white RAL 9003 with battery space for a 7 Ah 12 V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technica...

Page 2: ...p time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another net...

Page 3: ...witch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 7 Ah 12 V 7 Power supply connector...

Page 4: ...r supply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 48 W Table 4 Electrical parameters Mains supply 200 240 V 50Hz Current...

Page 5: ...ts and licenses applicable and required for a given country for 230 V and low voltage installations The device shall be mounted in confined spaces according to the environment class II with normal air...

Page 6: ...tor Connect the ground wire to the clip marked by the earth symbol Use a three core cable with a yellow and green protection wire to make the connection Lead the cables to the appropriate clips throug...

Page 7: ...THE PoE PORTS 1 4 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af stand...

Page 8: ...PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compres...

Reviews: