background image

 

Table 5. Mechanical parameters 

Dimensions 

W=280, H=291, D+D

1

=82+8 [+/- 2mm] 

W

1

=285, H

1

=295 [+/- 2mm] 

The dimensions of the battery 
compartment 

170 x 110 x 65mm (WxHxD) max 

Gross/Net weight 

2,7 / 2,9 kg 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power supply of the cameras: RJ45 socket 
Input 230 V AC

: Φ 0,63-2,50 (AWG 22-10) 

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

 
Table 6. Operation safety 

Protection class PN-EN 609501:2007  

I (first) 

Protection grade PN-EN 60529: 2002 (U)  

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU  
- between input circuit and protection circuit  
- between output circuit and protection circuit  

 

3000 V AC min. 
1500 V AC min. 
  500 V AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 

100 MΩ, 500V DC 

Declarations 

CE 

 

Table 7. Operating parameters

 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

2.  Installation 

2.1. Installation procedure 

The  device  should  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses  (applicable  and  

required  for  a  given  country)  for  230 V  and  low-voltage  installations.  

The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 

(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

The  switch  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow  through  ventilating  holes  of 
the enclosure.  

 
Before installation, prepare a Switch'a load balance.  

 
The  given  value  of  30  W  per  port  is  the  maximum  value  referring  to  a  single  output.  The  total  power 

consumption should not exceed 48 W. 

The increased demand for power is particularly evident in the case of cameras 

with  heaters  or  infrared  illuminators  -  when  launching  these  features,  the  power  consumption  increases  rapidly,  which 
may  adversely  affect  the  operation  of  the  switch.  As  the  device  is  designed  for  a  continuous  operation  and  is  not 
equipped  with  a  power-switch,  therefore  an  appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply 
circuit.  Moreover,  the  user  shall  be  informed  about  the method  of  unplugging  (usually  through  assigning  an  appropriate 
fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 
 

2.2.  Installation procedure 

 

 

Before installation, cut off the voltage in the 230 V power-supply circuit. 

               

To switch power off, use an external switch, in which the distance between the contacts of all 

poles in the disconnection state is not less than 3mm. 

 

 
 

2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (230 V) to L-N clips of the PSU.  
 
 
 
 

Summary of Contents for S64-B

Page 1: ...lor white RAL 9003 with battery space for a 7 Ah 12 V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technica...

Page 2: ...p time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another net...

Page 3: ...witch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 7 Ah 12 V 7 Power supply connector...

Page 4: ...r supply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 48 W Table 4 Electrical parameters Mains supply 200 240 V 50Hz Current...

Page 5: ...ts and licenses applicable and required for a given country for 230 V and low voltage installations The device shall be mounted in confined spaces according to the environment class II with normal air...

Page 6: ...tor Connect the ground wire to the clip marked by the earth symbol Use a three core cable with a yellow and green protection wire to make the connection Lead the cables to the appropriate clips throug...

Page 7: ...THE PoE PORTS 1 4 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af stand...

Page 8: ...PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compres...

Reviews: