5
Table 5. Mechanical parameters
Dimensions
W=280, H=291, D+D
1
=82+8 [+/- 2mm]
W
1
=285, H
1
=295 [+/- 2mm]
The dimensions of the battery
compartment
170 x 110 x 65mm (WxHxD) max
Gross/Net weight
2,7 / 2,9 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front), (lock assembly possible)
Connectors
Power supply of the cameras: RJ45 socket
Input 230 V AC
: Φ 0,63-2,50 (AWG 22-10)
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class PN-EN 609501:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU
- between input circuit and protection circuit
- between output circuit and protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V DC
Declarations
CE
Table 7. Operating parameters
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation
2.1. Installation procedure
The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and
required for a given country) for 230 V and low-voltage installations.
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity
(RH=90% max. without condensation) and the temperature from -
10°C to +40°C.
The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of
the enclosure.
Before installation, prepare a Switch'a load balance.
The given value of 30 W per port is the maximum value referring to a single output. The total power
consumption should not exceed 48 W.
The increased demand for power is particularly evident in the case of cameras
with heaters or infrared illuminators - when launching these features, the power consumption increases rapidly, which
may adversely affect the operation of the switch. As the device is designed for a continuous operation and is not
equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply
circuit. Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate
fuse in the fuse-box). The electrical system shall follow valid standards and regulations.
2.2. Installation procedure
Before installation, cut off the voltage in the 230 V power-supply circuit.
To switch power off, use an external switch, in which the distance between the contacts of all
poles in the disconnection state is not less than 3mm.
2. Mount the PSU in a selected location and connect the wires.
3. Connect the power cables (230 V) to L-N clips of the PSU.