background image

 

 

 

 

 
 
 

 

3.  Operation indication (See Table 4

)

 
Table 4. Operation indication.

 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

GREEN LED LIGHT (Power) 
Indication of the switch's 
power supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION AT THE PoE PORTS (1

÷4) 

DIODA LED ZIELONA (PoE) 
Indication of the PoE power 
supply 
at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant 

with the IEEE802.3af standard) 

ON

 

– supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10MB/s or 100Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected ; 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UPLINK PORT 

GREEN LED LIGHT 

 

 

OFF

- no connection 

ON 

– the device is connected ; 10Mb/s or 100Mb/s 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10MB/s or 100Mb/s 
and data transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected : 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

 
 

 
 

 
 
 

 
 

 
 
 

Summary of Contents for S54-CR

Page 1: ...03 warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The S54 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another ne...

Page 2: ...ntiometer adjusting the output voltage of the power supply 46 52V 4 LED light power supply operation indication 5 F 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the 48VDC 1 2A 60W power supply of the recorder desktop type 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x100mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 The enclosure...

Page 3: ...ard Optical indication of operation Switch power supply Link Act PoE Status Power supply 90 264VAC 50 60Hz 1 2A 230VAC Operating conditions temperature 10 C 45 C relative humidity 5 90 no condensation Dimensions W x H x D Switch 118 x 28 x 85 mm Enclosure 540 x 440 x 110 14 mm Enclosure Steel plate DC01 1 0mm color white RAL 9003 Closing Cheese screw x 2 at the front lock assembly possible Notes T...

Page 4: ...f the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be made in accordance...

Page 5: ...cted or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is c...

Page 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...