background image

 

 

           

1.2 Block diagram. 

 

 

Fig. 1. Block diagram. 

 

          1.3. Description of components and connectors. 
 
       Table 1. (see Fig.2) 

Element no. 

(Fig. 2) 

Description 

[1] 

Switch 

[2] 

Switch mode power supply for the switch 48VDC/1,2A/60W 

[3] 

Potentiometer adjusting the output voltage of the power supply (46

÷52V)

 

[4] 

LED light 

– power supply operation indication 

[5] 

F 6,3A / 250V fuse socket 

[6] 

Mounting brackets for cables 

[7] 

Space for the 48VDC/1,2A/60W power supply of the recorder (desktop type)

 

[8] 

Power Socket of the 230V AC recorder 

[9]

 

Recorder space of dimensions max 400x345x100mm WxHxD  

[10] 

Straps for attaching the DVR in enclosure 

 

Fig. 2 The enclosure view. 

Summary of Contents for S54-CR

Page 1: ...03 warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The S54 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another ne...

Page 2: ...ntiometer adjusting the output voltage of the power supply 46 52V 4 LED light power supply operation indication 5 F 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the 48VDC 1 2A 60W power supply of the recorder desktop type 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x100mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 The enclosure...

Page 3: ...ard Optical indication of operation Switch power supply Link Act PoE Status Power supply 90 264VAC 50 60Hz 1 2A 230VAC Operating conditions temperature 10 C 45 C relative humidity 5 90 no condensation Dimensions W x H x D Switch 118 x 28 x 85 mm Enclosure 540 x 440 x 110 14 mm Enclosure Steel plate DC01 1 0mm color white RAL 9003 Closing Cheese screw x 2 at the front lock assembly possible Notes T...

Page 4: ...f the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be made in accordance...

Page 5: ...cted or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is c...

Page 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...