4.

 

Operation and use.

  

 

4.1

 

Overload or short circuit of the PSU output (SCP on).

  

In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of the voltage 

takes place immediately after the failure (overload) is over.  

 

4.2

 

Disconnection of discharged battery

.  

The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing 

voltage below 9,5V at the battery terminals will cause battery disconnection.  

 

4.3 Maintenance

.  

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the  power  supply 

network. The PSU   does not require performing any specific maintenance measures, however, in case of significant dust rate, 
its interior is recommended to be cleaned with compressed air. In case of fuse replacement, use a replacement of the same 
parameters.  

 

 
 

 
 
 
 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household waste. 
According  to  the  European  Union  WEEE  Directive,  waste  electrical  and  electronic  equipment 

should be disposed of separately from normal household waste

 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the 

applicable law.

 

 

 
 

 

 
 
 
 
 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (manufacturer) grants a two-year quality warranty for the equipment, starting from the production date. 
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the manufacturer) if the 
malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that such defects have been 
reported within the warranty period (point.1). 
3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the 
manufacturer. 
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.  
5.  Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not 
later that within 14 days from the delivery to the service centre of the manufacturer. 
6.  The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 
7.  All the services are carried out at the service centre of the manufacturer, exclusively. 
8. The warranty does not cover the defects of the equipment, resulting from:  

Summary of Contents for S54-B17

Page 1: ...s 1K size Metal enclosure color white RAL 9003 with battery space for a 12V 17Ah battery warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Indication of the device operation 3 1 LED indica...

Page 2: ...tion of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is housed in a metal enclosure color RAL 9003 which can accommodate a 1x17Ah 12V battery The enclosure features a micro switch tamper indicating door opening front panel The S54 B17 is fitted with two LEDs on the front panel red LED indicates 230VAC power supp...

Page 3: ...h PoE 2 Switch mode buffer power supply unit 3 DC DC48125 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 12V 17Ah battery 7 Power supply connector of the PSU L N PE protective connector electric shock 8 BAT BAT battery output BAT red BAT black Fig 3 The view of the switch ...

Page 4: ...rrent up to 0 7A 230VAC max Supply power 55W Output current at the PoE ports RJ45 4 x 0 3A ΣI 1A max Output voltage at the PoE ports RJ45 48VDC Short circuit protection SCP and overload protection OLP 105 150 PSU power manual restart the fault requires disconnection of the DC output circuit PSU current consumption 100mA Battery charge current 0 5A max 1x17Ah 5 Battery circuit protection SCP and re...

Page 5: ... illuminators when launching these features the power consumption increases rapidly which may adversely affect the operation of the switch As the device is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually ...

Page 6: ...Y 1 4 DIODA LED ZIELONA PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is conn...

Page 7: ...apted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law GENERAL WARRANTY CONDITIONS 1 Pulsar manufacturer grants a two year quality warranty for the equipment starting from the production date 2 The warranty includes free of charge repair or replacement with an appropriate equivalent selected by the manufacturer if...

Page 8: ...8 Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl ...

Reviews: