background image

 

 
3. Indication of the device operation. 
 

3.1 LED indication of operating status. 

The PSU is equipped with two diodes on the front panel: 

 

 

 
RED LED: 

 

on – the PSU is supplied with 230V AC  

 

off – no 230V AC supply 

 
GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

 

 

 

 

3.2 Optical indication of the switch operation (see Table 8). 

 

Table 8. Indication of the switch operation 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

 

GREEN LED LIGHT (Power) 
Indication of the switch's 
power supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY (1

÷4) 

 

DIODA LED ZIELONA (PoE) 
Indication of the PoE power 
supply at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant with 

the IEEE802.3af standard) 

ON

 

– supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10MB/s or 100Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UPLINK PORT 

 

GREEN LED LIGHT 

 

 

OFF

- no connection 

ON 

– the device is connected; 10Mb/s or 100Mb/s 

YELLOW LED LIGHT (LINK) 
The connection status of 
LAN devices, 10MB/s or 
100Mb/s 
and data transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected: 10Mb/s or 100Mb/s 

Blinking

 

– data transmission 

 

 
 

 

 

Installation example of the S54-B17 battery  

(Battery not included) 

Summary of Contents for S54-B17

Page 1: ...s 1K size Metal enclosure color white RAL 9003 with battery space for a 12V 17Ah battery warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Indication of the device operation 3 1 LED indica...

Page 2: ...tion of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is housed in a metal enclosure color RAL 9003 which can accommodate a 1x17Ah 12V battery The enclosure features a micro switch tamper indicating door opening front panel The S54 B17 is fitted with two LEDs on the front panel red LED indicates 230VAC power supp...

Page 3: ...h PoE 2 Switch mode buffer power supply unit 3 DC DC48125 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 12V 17Ah battery 7 Power supply connector of the PSU L N PE protective connector electric shock 8 BAT BAT battery output BAT red BAT black Fig 3 The view of the switch ...

Page 4: ...rrent up to 0 7A 230VAC max Supply power 55W Output current at the PoE ports RJ45 4 x 0 3A ΣI 1A max Output voltage at the PoE ports RJ45 48VDC Short circuit protection SCP and overload protection OLP 105 150 PSU power manual restart the fault requires disconnection of the DC output circuit PSU current consumption 100mA Battery charge current 0 5A max 1x17Ah 5 Battery circuit protection SCP and re...

Page 5: ... illuminators when launching these features the power consumption increases rapidly which may adversely affect the operation of the switch As the device is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually ...

Page 6: ...Y 1 4 DIODA LED ZIELONA PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is conn...

Page 7: ...apted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law GENERAL WARRANTY CONDITIONS 1 Pulsar manufacturer grants a two year quality warranty for the equipment starting from the production date 2 The warranty includes free of charge repair or replacement with an appropriate equivalent selected by the manufacturer if...

Page 8: ...8 Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl ...