1.4. Technical parameters (table 2.) 

 

       

Table 2. 

            

Ports 

8 x PoE (10/100Mb/s) (RJ-45) 

 2 x UPLINK (10/100/1000Mb/s) (RJ-45) 

with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷8 ports),  48VDC / 15,4W at each port *   

Used pairs  1/2  (+),  3/6 (-) 

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 

100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply  

Link 

SPD 

PoE Status 

Power supply 

90 ÷ 264VAC 50÷60Hz / 0,6A  230VAC max. 

the PSD 480250 48VDC/2,5A/120W max. power supply desktop type 

Operating conditions 

temperature -

10°C ÷ 45°C,  

relative humidity  20% - 90%, no condensation 

Dimensions (W x H x D) 

220 x 44 x 150 [mm] 

Additional equipment 

plate to be fixed surface, bracket for 

Rack 19” 

Net/gross weight 

1,69/1,93kg 

  

Protection class        
EN 60950-1:2007 

I (first) 

Storage temperatur 

-

20°C ÷ 60°C 

Declarations 

CE 

*

 

The given value of 15,4W per port is the maximum value. The total power consumption should not exceed 96W when all PoE ports are being used. 

 

 2.

 

Installation. 

 

2.1. Requirements. 

           The  unit  should  be  mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal 
relative humidity (RH=90% maximum, without condensation) and temperature from -

10°C to +45°C. Ensure the free flow 

of  air  around  the  unit.  The  PSU  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow  through 
ventilating holes of the enclosure.  
The  switch  load  balance  should  be  done  before  installation.  The  given  value  of  15,4W  per  port  is  the  maximum  value 
referring to a single output. The total power consumption should not exceed 96W when all PoE ports are being used. The 
increased  demand  for  power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -  when 
launching  these  features,  the  power  consumption  increases  rapidly,  which  may  adversely  affect  the  operation  of  the 
switch. As the device is designed for a continuous operation and is not equipped with a power-switch, therefore  an appropriate 
overload  protection  in  the  power  supply  circuit  should  be  provided.  The  electrical  system  shall  be  made  in  accordance  with 
applicable standards and regulations. 

 

 

2.2.  Installation procedure. 

1. Connect switch to the PSD480250 48VDC power supply unit desktop type.    

 

2. Connect the power supply to the AC 230V socket. 
3. Connect the camera wires to the RJ45 connectors (PoE connectors (sockets RJ45 from 1 to 8). 
4. Check the optical indication of switch operation (see Table 3). 
 

 

 

 

 

 

 

 

 
            

Summary of Contents for S108

Page 1: ... from the production date Example of use 1 Technical description 1 1 General description S108 is a 10 port PoE switch designed to supply IP cameras operating in IEEE 802 3af standard Automatic detection of any devices powered in the PoE standard is enabled at the 1 8 ports of the switch The G1 and G2 ports is used for connection of another network device The LEDs at the front panel indicate the op...

Page 2: ...diagram Fig 1 Block diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 8 x PoE port 1 8 2 2 x UPLINK port G1 G2 3 Power Socket of the 48VDC Fig 2 The view switch a ...

Page 3: ...th the 2nd environmental class with normal relative humidity RH 90 maximum without condensation and temperature from 10 C to 45 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation The given value of 15 4W per port...

Page 4: ...4 Connection schemes ...

Page 5: ...ected or not compliant with the IEEE802 3af standard ON supply Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection or the device is connected 10Mb s ...

Page 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Reviews: