background image

www.pulsar.pl

    

 

 

 

RUPS824P 

 

 

  

           

RACK POWER 

 

 

Features: 

 

 

DC 27,6V/8x1A uninterruptible power supply 

 

8 outputs independently protected with 1A 
polymer fuses  

 

wide range of mains supply AC: 176

÷264V AC 

 

high efficiency 85% 

 

built-in power factor correction system (PFC) 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

battery output protection against short circuit and 
reverse connection 

 

battery charge current: 1A 

             (

batteries 2×7Ah / 2x17Ah / 2x28Ah) 

 

control of voltage presence at the 

AUX1 ÷ AUX8 

outputs 

 

acoustic indication of failure 

  LED optical indication: AC, DC, TEMP, LoB, ALARM, 

AUX1 ÷ AUX8 

  the ALARM technical output of collective failure 

–relay 

type, activated by:  

    230V AC power loss 

    low voltage of the PSU (<23V) 

    activation of the output fuse 

    too high temperature of the PSU (>70

°C) 

    the PSU failure  

  protections: 

    SCP short-circuit protection 

    OVP overvoltage protection 

    overvoltage protection 

    overload protection OLP 

    forced cooling (fan) 

  warranty 

– 2 year from the production date  

 

 

Sample application of the RACK power supply unit. 

 

 

 
 
 
 
 
 
 

Summary of Contents for RUPS824P

Page 1: ...RUPS824P v 1 0 RUPS 27 6V 8x1A PTC RACK mounted buffer power supply EN Edition 2 from 30 03 2017 Supercedes the edition 1 from 16 08 2016 ...

Page 2: ...arge current 1A batteries 2 7Ah 2x17Ah 2x28Ah control of voltage presence at the AUX1 AUX8 outputs acoustic indication of failure LED optical indication AC DC TEMP LoB ALARM AUX1 AUX8 the ALARM technical output of collective failure relay type activated by 230V AC power loss low voltage of the PSU 23V activation of the output fuse too high temperature of the PSU 70 C the PSU failure protections SC...

Page 3: ...cay a battery back up is activated immediately The PSU is fitted with 8 outputs protected independently with polymer fuses PTC 1A The power supply is fitted with the ALARM output of collective failure In case of failure relay contacts are switched automatically which is accompanied by acoustic and optical indication the corresponding led goes on The power supply construction is based on the switch...

Page 4: ...cal output of collective failure relay BUZZER micro switch turning ON OFF of acoustic indication switch in the top position indication ON switch in the down position indication OFF 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 6 3A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Page 5: ...e ALARM technical output of collective failure Relay type 1A 30VDC 50VAC FMAINS fuse in the power supply circuit 230V T 6 3A Mechanical parameters tab 3 Enclosure dimensions W 19 H 2U 482 x 88 x 223 mm WxHxD Fixation four point butt mounting to RACK profiles the set include 4 M6 screws cage nuts Net weight 5 8kg 6 2kg Enclosure Steel plate RAL 9005 black Connectors 230V AC input the IEC C14 socket...

Page 6: ...d about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the power supply in a RACK 19 cabinet as shown below Mount M6 cage nuts Secure the enclosure with 4xM6 screws 3 Connect the rece...

Page 7: ...ctive failure can be triggered by the following events 230V AC mains power failure Activation of the polymer fuse PTC Failure of the switch mode power supply Too high temperature of the switch mode power supply 70 C Low battery voltage 23V Fig 4 Electrical diagram of the ALARM collective output of failure CAUTION In Fig 4 the set of contacts shows a potential free status of the relay which corresp...

Page 8: ...ge below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment ...

Reviews: