background image

www.pulsar.pl

    

 

 

 

RSUPS98 

 

 

  

            

RACK POWER 

 

 

10 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household 

waste. According to the European Union WEEE Directive, waste electrical and electronic 

equipment should be disposed of separately from normal household waste

 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (manufacturer) grants a two-year quality warranty for the equipment, starting from the production date. 

2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the 
manufacturer) if the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that 

such defects have been reported within the warranty period (point.1). 
3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the 

manufacturer. 
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the 

defect.  
5.  Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, 

however not later that within 14 days from the delivery to the service centre of the manufacturer. 
6.  The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, 

or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 
7.  All the services are carried out at the service centre of the manufacturer, exclusively. 

8. The warranty does not cover the defects of the equipment, resulting from:  
- reasons beyond the manufacturer's control,  

- mechanical damage,  
- improper storage and transport,  

- use that violates the operation manual or equipment’s intended use  
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,   

- improper installation and configuration (failure to follow instruction). 
9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in 

case of damage or modifications to warranty stickers and serial numbers. 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to 

the wholesale prices suggested by the manufacturer on the day of purchase. 
11.  The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to 

operate the equipment especially when resulting from failure to comply with the recommendations and requirements 
contained in the manual. 

 

 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Polska 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

Summary of Contents for RSUPS98

Page 1: ...RSUPS98 v 1 0 9 port switch for 8 IP cameras IP with battery backup for cameras RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Page 2: ...ports 8 PoE ports data transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge c...

Page 3: ...itch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device This method allows supplying other network devices such...

Page 4: ...ation ON switch in the down position indication OFF PoE port 1 8 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Page 5: ...ward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 110W max Output voltage at the PoE ports 48V DC maintained regardless of the state of b...

Page 6: ... waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and necessary for a given country The device shall be mount...

Page 7: ...onnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V ...

Page 8: ...on ON the device is connected 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the followin...

Page 9: ...utage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply netw...

Page 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...