![Pulsar PSUPS20A12CR Manual Download Page 7](http://html1.mh-extra.com/html/pulsar/psups20a12cr/psups20a12cr_manual_1625128007.webp)
www.pulsar.pl
PSUPS20A12CR
7
Table 5. Mechanical specifications.
Dimensions
W=420, H=535, D+D
1
=193+14 [+/- 2mm]
W
1
=425, H
1
=540 [+/- 2mm]
The dimensions of the
recorder compartment
W
2
=380, H
2
=320, D
2
=65 [+/- 2mm]
The dimensions of the
battery compartment
380 x 340 x 175 mm (WxHxD) max
Fixing
See Fig. 3
Net/gross weight
8,8/9,6 kg
Enclosure
Steel plate DC01 1,0mm, colour RAL 9003
Closing
Cheese head screw x2 (at the front)
The possibility of installing two locks with different codes.
Connectors
Mains supply:
Φ0,63-2,50 (AWG 22-10)
Outputs for cameras
: Φ0,63-2,50 (AWG 22-10)
Recorder outputs: power cord 55cm, terminated with the DC 5,5/2,1 plug
Battery outputs:
Ф6/2,5mm
2
TAMPER output: wires
Notes
The enclosure does not adjoin the assembly surface so that cables can be led.
Forced cooling - built-in fan.
Table 6. Operation safety.
Protection class EN 60950 -1:2007
I (first)
Protection grade EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of the PSU
- between input circuit and protection circuit
- between output circuit and protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100MΩ, 500V DC
Table 7. Operating specifications
Environmental class
II
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insolation
unacceptable
Vibrations and impulse waves during transport
Wg PN-83/T-42106
Chart 1. Acceptable output current from the PSU depending on ambient temperature.