Pulsar PSDCB05125C Manual Download Page 2

www.pulsar.pl                                                             PSDCB05125C            

 
 

 

2

 

Features: 

 

 

DC 13,8V/5A uninterruptible power supply  

 

5 outputs, protected with 1A glass fuses  

 

fitting battery: 17Ah/12V  

 

wide range of mains supply: 176÷264V  

 

high efficiency 80% 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

    battery charging current 1A/2A changed with 

jumper 

 

 

battery output full protection against short-circuit 
and reverse polarity connection  

 

LED indication  

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

overvoltage protection   

 

against sabotage 

 

overload protection (OLP) 

 

warranty – 2 year from the production date

 

 

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors. 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output (SCP on) 
4.2 

Battery-assisted operation 

4.3 Maintenance 

 

 
 
1. Technical description. 
 

1.1 General description. 

A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised voltage of 

12 V DC  

(+/-15%).

 The PSU provides voltage of 

U=13,8 V DC.

 Current efficiency: 

 

 

1.  Output current 5x1A + 1A battery charge 
2.  Output current 5x1A + 2A battery charge 

                                              Total device c battery: 7A max. 

 

In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the 

switch mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which 
can accommodate a 17Ah/12V battery. A micro switch indicates door opening (front cover). 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for PSDCB05125C

Page 1: ...PSDCB05125C v 1 0 PSDCB 13 8V 5A 5x1A 17Ah Buffer switch mode power supply for CCTV EN Edition 2 from 25 11 2013 Supercedes the edition 1 from 31 01 2013 GREEN POWER CCTV ...

Page 2: ...ts and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication of operating status 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to devices r...

Page 3: ...of the fuse block LB5 Tabela 2 Description of PSU components and connectors fig 3 Element no Fig 3 Description 1 PSU module 2 L N power supply connector 230V AC PE protection connector 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Ibat Sel...

Page 4: ...tage 11V 13 8V DC buffer operation 9 5V 13 8V DC battery assisted operation Output current 5x1A 1A battery charge 5x1A 2A battery charge Output current tAMB 30 C 5x1 A 1A battery charge refer to chart 1 5x1 A 2A battery charge refer to chart 1 Output current tAMB 40 C 5x0 8 A 1A battery charge refer to chart 1 5x0 6A 2A battery charge refer to chart 1 Voltage adjustment range 12 14VDC Ripple 120mV...

Page 5: ...0 7mm colour RAL 9003 Closing Cheese head screw x 2 at the front lock assembly possible Connectors Power supply Φ0 63 2 50 AWG 22 10 OutputsФ0 41 1 63 AWG 26 14 battery output BAT 6 3F 2 5 TAMPER output wires Notes The enclosure does not adjoin the assembly surface so that cables can be led Operation safety tab 5 Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP20 ...

Page 6: ...circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and connect the wires 3 Connect the power cables 230VAC...

Page 7: ...se of fuse damage the replacement of the same parameters is required In case of overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immediately switched into a battery assisted operation The PSU is equipp...

Page 8: ...hat within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of th...