background image

 

1.3. Accessories. 

For the power supplies are available accessories - fuse blocks and cable adapter. For details 

–visit www.pulsar.pl  

2. Installation.  

2.1. Requirements. 

The power supply shall be mounted by the qualified installer having appropriate (required and necessary for a given country) 

permissions and qualifications for connecting (operating) low-voltage installations. The power supply shall be mounted in closed rooms, 
according to the environment class II, of the normal air humidity (RH=90% max.) and the temperature within the range from  -

10°C to 

+40°C.  

 

The power supply load balance should be done before installation. During normal operation, the total  current of the 

receivers should not exceed I=1 A. The maximum battery charging current is 0,3 A. The total current of the rec battery 
is max. 1,3 A. 

The  power  supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch. Therefore, an 

appropriate  overload  protection  in  the  power  supply  circuit  should  be  provided.  Moreover,  the  user  should  be  informed  how  to 
disconnect  the  power  supply  unit  from  the  mains  supply  (usually  by  assigning  an  appropriate  fuse  in  the  fuse  box).  The  electrical 
system shall be made in accordance with applicable standards. In order to meet the LVD and EMC requirements, the rules concerning 
power supply, building-in and shielding should be followed accordingly.  

 

2.2. Installation procedure. 

1.  Before installation, make sure that the voltage in the 230 V power-supply circuit is cut off. 
2.  Install the power supply. 
3.  Connect the power supply to the 230 V line. The power supply has to be installed in such way to keep the air flow around the 

supply unit. 

4.  Connect the DC output to the load/loads. 
5.  Switch on the 230 V supply. 
6.  Connect the battery in accordance with the markings: +BAT red to 'plus', -

BAT black to 'minus’. 

 

7.  Close the enclosure, cabinet, etc. after installing and checking the operation of the power supply.  

 

3. Maintenance. 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  power  supply  from  the  power 

network. The power supply does not require any specific maintenance procedures, however, in the case of significant level of dust, it 
should be cleaned with the compressed air.  

                          

WEEE designation  

 
The  waste  electric  and  electronic  equipment  worn  out  may  not  be  disposed  of  together  with 
standard household waste. According to the WEEE directive, applicable in the EU, the separate 
neutralization methods should be used for electric and electronic equipment. 
 

 
 
 

 
 

 

 

 

 
 
 

 

Pulsar sp. j. 

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]