RED LED: 

 

on – the PSU is supplied with 230V AC  

 

off – no 230V AC supply  

 

GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

3. Indications. 

 
3.1 LED indication. 

The PSU is equipped with two diodes on the front panel:

 

 

 

 

 

 

 
Moreover, the PSU is equipped with three diodes: AC, LB, AUX. They are placed on the PCB of the PSU 

and indicate its operation status. 

 

AC - red diode

: under normal status (AC supply) the diode is permanently illuminated. The absence of AC 

supply is indicated by the AC diode going off.  

 

LB  -  red  diode

:  indicates  the  battery  charging  process;  the  intensity  of  illumination  is  dependent  on  the 

charging current. 

 

AUX 

green  diode

:  indicates  the  DC  supply  status  in  the  output  of  the  PSU.  Under  normal  status,  the 

diode is permanently illuminated. In case of short-circuit or overload, the diode goes off.

 

 
3.2 Technical outputs:  

The PSU is equipped with indication outputs. 
 

 

FAC  -  absence  of  AC  supply output

:  -  relay  output indicating  absence  of  AC  supply.  In  case  of  power 

loss, the PSU will switch the relay contacts after a time period set by the T

AC 

jumpers (J1, J2). 

 

Caution!

 In Fig.2. the contact set in the potential-free status corresponds to a state with no AC 

power (AC power failure). 
 

 

 

TAMPER  -  output  indicates  opening  the  power-supply  unit: 

volt-free  (potential-free)  contacts  in  the 

output indicate the door status, unit closed: NC, unit opened: NO 

 
4. Operation and use. 

4.1 Overloads or short circuits. 

The AUX output of the PSU is equipped with the PTC polymer fuse protection. If the load exceeds 

I

max. 

(load 110% ÷ 150% @25ºC of the PSU  power), the output voltage is automatically cut off and indicated by the 
green diode going off. Cut off the output load for approximately 1 minute to restore the output power. 
 

In the case of the short-circuit to the AUX, BAT output, (load 200% ÷ 250% of the PSU power) or incorrect 

connection of the battery, the fuse F

BAT

 in the battery circuit becomes permanently damaged and the restoration of 

the voltage at the BAT output requires the replacement of the fuse. 

 

4.2 Battery-powered operation.  

Battery reverting in case of main power outage.

 

In order to run the PSU from the battery only, connect the BAT connectors in accordance with the signs:  

+ BAT red to ‘plus’ and, - BAT black to 'minus’ then press the START button on the main board and hold it for 5 
seconds. 

 

The PSU contains the discharged battery disconnection system (UPV), configured through 
the P

BAT

 pins. The battery protection is on after removing the P

BAT

 jumper. 

 
 

4.3 Maintenance. 
 

Any and all maintenance operations may be performed following the disconnection of the PSU from the 

power supply network. The PSU   does not require performing any specific maintenance measures, however, in 
case of significant dust rate, its interior is recommended to be cleaned with compressed air. In case of fuse 
replacement, use a replacement of the same parameters. 

 
 
 

Summary of Contents for PSBS 1512A

Page 1: ...PSBS 1512A v 1 0 PSBS 13 8V 1A 1 2Ah Buffer switch mode power supply unit EN Edition 3 from 16 09 2013 Supersedes edition 2 from 18 09 2012...

Page 2: ...1 Overloads or short circuits 4 2 Battery powered operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer PSU is used for an uninterrupted supply to alarm systems devices...

Page 3: ...n J1 J2 time lag T 5s J1 J2 time lag T 140s J1 J2 time lag T 1040s 17m 20s J1 J2 time lag T 2h 20m 30s Legend jumper installed jumper removed 2 START button launching from battery 3 VADJ potentiometer...

Page 4: ...Part no Description 1 Isolation transformer 2 Power upply unit board tab 1 fig 2 3 TAMPER microswitches contacts for sabotage protection NC 4 FMAIN fuse in the power supply circuit 230V AC 5 L N conn...

Page 5: ...eplacement required Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT battery configuration by the PBAT jumper Technical outputs FAC indicates AC power failure TAMPER indicates enclos...

Page 6: ...N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the ap...

Page 7: ...e output indicate the door status unit closed NC unit opened NO 4 Operation and use 4 1 Overloads or short circuits The AUX output of the PSU is equipped with the PTC polymer fuse protection If the lo...

Page 8: ...ies to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out...

Reviews: