background image

www.pulsar.pl   

 

 

 

PSBS1512A 

 

 

 

 

 
 

 

Fig.2. View of the power supply pcb. 

Table 2. Parts of the power supply (refer to chart 3). 

Part no. 

Description 

[1] 

Isolation transformer 

[2] 

Power upply unit board

 

(tab. 1, fig. 2) 

[3] 

TAMPER; 

microswitches (contacts) for sabotage protection

 (NC) 

[4] 

F

MAIN

 

fuse in the power supply circuit (230V/AC) 

[5] 

 L-N  

connector 230V/AC, 

 PE protection connector

 

[6] 

Battery connBAT = red, - BAT = black 

 

 

Fig.3. The view of the power supply. 

 

Summary of Contents for PSBS 1512A

Page 1: ...PSBS 1512A v 1 0 PSBS 13 8V 1A 1 2Ah Buffer switch mode power supply unit EN Edition 3 from 16 09 2013 Supersedes edition 2 from 18 09 2012...

Page 2: ...1 Overloads or short circuits 4 2 Battery powered operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer PSU is used for an uninterrupted supply to alarm systems devices...

Page 3: ...n J1 J2 time lag T 5s J1 J2 time lag T 140s J1 J2 time lag T 1040s 17m 20s J1 J2 time lag T 2h 20m 30s Legend jumper installed jumper removed 2 START button launching from battery 3 VADJ potentiometer...

Page 4: ...Part no Description 1 Isolation transformer 2 Power upply unit board tab 1 fig 2 3 TAMPER microswitches contacts for sabotage protection NC 4 FMAIN fuse in the power supply circuit 230V AC 5 L N conn...

Page 5: ...eplacement required Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT battery configuration by the PBAT jumper Technical outputs FAC indicates AC power failure TAMPER indicates enclos...

Page 6: ...N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the ap...

Page 7: ...e output indicate the door status unit closed NC unit opened NO 4 Operation and use 4 1 Overloads or short circuits The AUX output of the PSU is equipped with the PTC polymer fuse protection If the lo...

Page 8: ...ies to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out...