Pulsar PSBOC754813 Quick Start Manual Download Page 8

www.pulsar.pl 

 

 

 

 

PSBOC754813 

 

 

 

 

 
 

 

                         

 

WEEE MARK 

 

 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 

electronic waste as unsorted municipal waste and to collect such WEEE separately.

 

 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

GENERAL WARRANTY CONDITIONS 

 
1. Pulsar (the manufacturer) grants a two-year warranty for the equipment, counted from the device’s production date. 

2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 

defects have been reported within the warranty period (item 1).  
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 

manufacturer.  
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   

5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however 
not later that within 14 days from the delivery to the service centre of the manufacturer.  

6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  

7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  

8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 

- mechanical damage, 
- improper storage and transport, 

- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  

- improper installation and configuration (in defiance with the manual), 
9. The warranty is void in any of the following circumstances: 

- construction changes  
- repairs carried out by any unauthorized service center 

- damage or removal of warranty labels 
- modifications of the serial number 

10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  

11. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 

- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 

recommendations and requirements contained in the manual, or the use of the equipment.  

 

Summary of Contents for PSBOC754813

Page 1: ...PSBOC754813 v 1 0 PSBOC 54V 1 3A OC Enclosed buffer switch mode power supply unit with technical outputs EN Edition 2 from 01 06 2016 Supercedes edition 1 from 13 05 2016 ...

Page 2: ...TS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication of operating status 3 2 Technical outputs 4 Operation and use 4 1 Overload or short circuit of the PSU output 4 2 Battery assisted operation 4 3 Maintenanc...

Page 3: ...bsence technical output relay type 5 PSU output indicating DC absence PSU failure relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU output indicating DC absence PSU failure OC type 9 LoB output indicating battery low voltage OC type 10 V V DC supply output 11 L N 230V AC power connector PE protection connector 12 LED indication on the...

Page 4: ...oad protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection polymer fuse Surge protection varistors Surge over voltage protection OVP 62V automatic recovery Deep discharge protection UVP U 38V 5 disconnection of the battery terminal Technical outputs EPS output indicating AC power failure PSU output indicating DC absence PSU failure ...

Page 5: ...ounted in confined spaces in accordance with the 2nd environmental class with normal relative humidity RH 90 maximum without condensation and temperature from 10 C to 40 C The device shall be mounted in a metallic enclosure a cabinet an intended case In order to fulfil LVD and EMC requirements the rules for power supply encasing and screening shall be followed according to application During norma...

Page 6: ...ted AC power absence is indicated by the AC diode going out green LED Fig 2 element 2 indicates DC power at the PSU output Under normal status the diode is permanently illuminated In case of a short circuit or an overload the diode is off green LED Fig 2 element 3 indicates battery voltage level Under normal status UBAT 46V the diode is permanently illuminated In case of decrease of battery voltag...

Page 7: ...rease of battery voltage UBAT 46V the output is switched into high impedance state hi Z relay output In case of a battery voltage drop UBAT 46V the contacts of the relay change over The power supply unit does not feature a battery detection function In the case of no battery or non battery connected the output is in the normal mode CAUTION In the Fig 5 the set of contacts shows a potential free st...

Page 8: ...days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer...

Reviews: