                                               WEEE MARK 

 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 

electronic waste as unsorted municipal waste and to collect such WEEE separately.

 

 
 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law.

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (the manufacturer) grants a two-year warranty for the equipment, counted from the device’s production date. 
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 

manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1).  

3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  

4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however 

not later that within 14 days from the delivery to the service centre of the manufacturer.  

6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  

7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
8. The warranty does not cover the defects of the equipment, resulting from: 

- reasons beyond the manufacturer's control, 
- mechanical damage, 

- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 

9. The warranty is void in any of the following circumstances: 
- construction changes  

- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 

- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 

wholesale prices suggested by the manufacturer on the day of purchase.  

11. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 

- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

 

Summary of Contents for PSBOC501235

Page 1: ...PSBOC501235 v 1 1 PSBOC 13 8V 3 5A OC Enclosed buffer switch mode power supply unit with technical outputs EN Edition 8 from 01 06 2016 Supercedes edition 7 from 10 04 2015...

Page 2: ...TENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3...

Page 3: ...sence technical output relay type 5 PSU output indicating DC absence PSU failure relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU outpu...

Page 4: ...d protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection polymer fuse Surge protection varistors Surge over voltage protection OVP 16V...

Page 5: ...in confined spaces in accordance with the 2nd environmental class with normal relative humidity RH 90 maximum without condensation and temperature from 10 C to 40 C The device shall be mounted in a m...

Page 6: ...AC power absence is indicated by the AC diode going out green LED Fig 2 element 2 indicates DC power at the PSU output Under normal status the diode is permanently illuminated In case of a short circ...

Page 7: ...0V In case of decrease of battery voltage UBAT 11 5V the output is switched into high impedance state hi Z relay output In case of a battery voltage drop UBAT 11 5V the contacts of the relay change ov...

Page 8: ...ys from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equip...

Reviews: