WEEE LABEL 

 

According to the European Union WEEE Directive, waste electrical and electronic equipment should 

be disposed of separately from normal household waste. Waste electrical and electronic equipment 

must not be disposed of with normal household waste.

 

 

 

 

 

 CAUTION!

 

The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation 

period they must not be thrown but recycled according to the applicable law 

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  

32-744 Łapczyca, Poland 

Phone (+48) 14-610-19-40, Fax (+48) 14-610-19-50 

E-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

GENERAL WARRANTY CONDITIONS 

 
1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a five-year quality warranty for the equipment, starting from the production date.  

2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the manufacturer) if 
the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that such defects have been 

reported within the warranty period (point.1). 
3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the 

manufacturer. 
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.  

5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not 
later that within 14 days from the delivery to the service centre of the manufacturer. 

6. The repair period mentioned in point 5

 

may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 

equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 

7. All the services are carried out at the service centre of the manufacturer, exclusively. 

8. The warranty does not cover the defects of the equipment, resulting from:  
- reasons beyond the manufacturer's control,  

- mechanical damage,  
- improper storage and transport,  

- use that violates the operation manual or equipment’s intended use, 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,   

- improper installation and configuration (failure to follow instruction). 
9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in case of 

damage or modifications to warranty stickers and serial numbers. 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to the 

wholesale prices suggested by the manufacturer on the day of purchase. 
11. The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to operate 

the equipment especially when resulting from failure to comply with the recommendations and requirements contained in the 
manual. 

 

 

Summary of Contents for PSBEN 3024C/LCD

Page 1: ...PSBEN 3024C LCD v 1 1 PSBEN 27 6V 3A 2x17Ah EN LCD Buffer switch mode power supply unit EN Edition 5 from 18 06 2014 Supercedes edition 4 from 01 02 2013 LCD Version...

Page 2: ...STIC INDICATION 19 5 6 TECHNICAL OUTPUTS 19 5 7 INPUT OF COLLECTIVE FAILURE EXT IN 20 5 8 ENCLOSURE TAMPER INDICATION TAMPER 21 5 9 OVERVOLTAGE PROTECTION OF THE PSU OUTPUT OVP 21 5 10PSU OVERLOAD 21...

Page 3: ...ERY 35 8 REMOTE MONITORING OPTIONS WI FI ETHERNET RS485 USB 36 8 1 COMMUNICATION VIA THE USB TTL INTERFACE 36 8 2 ETHERNET NETWORK COMMUNICATION 36 8 3 THE WI FI WIRELESS COMMUNICATION 37 8 4 RS485 NE...

Page 4: ...d reverse polarity connection jumper selectable battery charging current 0 2A 0 6A 1A 1 5A remote battery test additional module required START button for battery activation STOP button for disconnect...

Page 5: ...re YES YES No battery charge YES YES Low output voltage YES YES High output voltage YES YES PSU failure YES YES Surge protection YES YES Short circuit protection YES YES YES YES Overload protection YE...

Page 6: ...n power source are reported to the Alarm Receiving Centre ARC in accordance with 9 2 EN 50131 1 standard Output voltage 0 28A 1 5A battery charge General use if the PSU is not mounted in an installati...

Page 7: ...dication off Caption jumper on jumper off VADJ potentiometer DC voltage adjustment BUZZER acoustic indicator FBAT fuse in the battery circuit Connectors AC AC power input BAT DC power battery output A...

Page 8: ...t no Description Insolation transformer PSU board see Tab 1 fig 2 TAMPER micro switch contacts of tamper resistance NC FMAINS fuse in the supply circuit 230V AC L N power supply connector 230V AC PE p...

Page 9: ...m 1 Mount the PSU in a selected location It is particularly important to bolt the tamper grip to the mounting surface The grip is located in the central part of the enclosure see fig 3 7 and guarantee...

Page 10: ...the PSU failure indication at the APS FLT output but it does not affect the protection system against complete battery discharge 11 Check the current consumption of the receivers taking into account...

Page 11: ...ntering the overview menu mode red LED indicating the presence of AC voltage green LED indicating power at the AUX output of the PSU red LED indicating the PSU failure 5 2 First run of the PSU languag...

Page 12: ...symbols Screen field Operating status Failure status Blinking FAIL message Information about the current voltage and power consumption at the AUX output The parameter which value has been exceeded is...

Page 13: ...www pulsar pl PSBEN3024C LCD BLACK POWER 13 current failures of the PSU see section 5 4 3 parameters of the PSU stored in the memory see section 5 4 4 History of events see section 5 4 5...

Page 14: ...ry charging indication highlighted battery charging PSU overload indication highlighted PSU overload Sections 5 10 PSU failure indication highlighted PSU failure Sections 5 4 6 5 6 Battery failure ind...

Page 15: ...of the highest priority If there are more than five failures at the same time use the or buttons to display the next failure 5 4 4 LCD screen history of the parameters To set the screen press the ESC...

Page 16: ...output current IAUX MIN output current minimum IAUX MAX output current maximum To optimally read and analyze the values shown in the chart it is possible to change the time range on the bottom axis of...

Page 17: ...appropriate code The codes are divided into two groups marked with the initial letters F or I The codes beginning with the letter F indicate a failure The codes that begin with the letter I indicate...

Page 18: ...FLT service codes F60 No communication PSU FLT no communication with LCD panel F61 F64 Control panel fail PSU FLT service codes F65 Access unlocked passwords unlocked Table 9 List of PSU message codes...

Page 19: ...to the open position after a time lag determined in the Delay time for EPS output menu see section 6 2 4 APS FLT output indicating battery failure The output indicates a failure in the battery circuit...

Page 20: ...e EXT IN input The electrical diagram below shows the way of connecting external devices to the EXT IN input Outputs such as OC open collector relay may be used as a source of the signal Fig 17 Exampl...

Page 21: ...n of the PSU output OVP In case of voltage exceeding 15 5V 0 5V at the switching regulator s output the system cuts off the power at the outputs to protect the battery and the receivers from damage Th...

Page 22: ...e password full access to the PSU s settings User s password locked access to the PSU settings menu Table 12 Access ranges PASSWORD Access range Control panel settings PSU settings SERVICE USER Preset...

Page 23: ...nge it To do this choose a password that will be changed user s password or service password and enter the new one 6 1 3 Disabling the password If the password is not required it can be turned off The...

Page 24: ...m by pressing the SET button When on the keyboard will be locked automatically if no buttons are pressed within 5 minutes After this time pressing any button on the control panel will display a window...

Page 25: ...N OFF battery test OFF Section 6 2 2 and 7 3 Battery protection ON battery protection disconnection ON OFF battery protection disconnection OFF Section 6 2 3 Delay time for EPS output Setting the dela...

Page 26: ...test menu press the SET button the prompt will appear at the end of the line use the or buttons to select ON battery test ON OFF battery test OFF confirm by pressing the SET button Enabling disabling...

Page 27: ...disconnection ON OFF battery protection disconnection OFF confirm by pressing the SET button 6 2 4 Setting the delay time for EPS output indicating 230V AC power loss The PSU features adjustable delay...

Page 28: ...tion between the PSU and the computer namely the address parity and speed should have the same settings for both the PSU and the PowerSecurity program Communication address allows to identify power su...

Page 29: ...ave the same settings for both the PSU and the PowerSecurity program The PSU has preset transmission parameters of 115200 baud 8E1 if these values were changed they should be restored to original sett...

Page 30: ...y mode the screen will turn off if no buttons are pressed within 5 minute Fig 23 Control panel screen Table 14 The description of the Control panel screen Position Description Language Available langu...

Page 31: ...the prompt will appear next to the day position use the or buttons to set the current day confirm by pressing the SET button 6 3 3 Setting the time The Time menu in the Control panel menu enables sett...

Page 32: ...option use the or buttons to change the setting to 5 min press the SET button the prompt will appear at the end of the line use the or buttons to set the required brightness confirm by pressing the S...

Page 33: ...during failure indication When on the blinking light will indicate a failure use the or buttons to display the Blinking light indicating failure menu press the SET button the prompt will appear at the...

Page 34: ...e SET button and select PSU Battery protection ON OFF see section 6 2 3 Caution Deactivating of the UVP function is not recommended since a deep discharge of the battery limits its capability of stori...

Page 35: ...s a battery circuit charged with direct current The current selection is done with use of the IBAT jumpers The table below shows how long does it take to charge a fully discharged battery up to min 80...

Page 36: ...e power supply unit power supply current consumption used for the calculation of standby time should be taken into account see section 7 4 8 1 Communication via the USB TTL interface The easiest way o...

Page 37: ...ng against adverse environmental conditions Fig 27 Ethernet network communication using the RS485 INTRE interface 8 3 The Wi Fi wireless communication The Wi Fi wireless communication can be implement...

Page 38: ...ainst adverse environmental conditions Fig 29 The Wi Fi communication using the RS485 WIFI INTRW interface 8 4 RS485 network communication Another type of network communication is the RS485 communicat...

Page 39: ...of the program into smaller areas depending on the number of monitored power supplies The program is equipped with manager mode which allows the grouping of power supplies for easier analysis and orie...

Page 40: ...voltage automatic return AUX disconnection Short circuit protection SCP Electronic current limitation and or FBAT fuse failure in the battery circuit requires fuse replacement Automatic return Overloa...

Page 41: ...mm 2 Mounting See Fig 3 Battery space 2x17Ah 12V SLA max 380 x 165 x 85mm WxHxD max Net gross weight 6 4 6 9 kg Enclosure Steel plate DC01 1mm color RAL 9005 black Closing Cheese head screw x2 at the...

Page 42: ...once per year During the inspection check the batteries and run the battery test 4 weeks after installation re tighten all screw connections see Fig 2 9 10 1 Battery replacement of the LCD panel Estim...

Page 43: ...www pulsar pl PSBEN3024C LCD BLACK POWER 43...

Page 44: ...the claim be accepted the manufacturer is obliged to provide warranty repairs at the earliest convenience however not later that within 14 days from the delivery to the service centre of the manufactu...

Reviews: