background image

www.pulsar.pl 

PSAC04244SEP 

   

 

 

 

Features of the power supply unit: 

 

 

   power output 4x 1A/24V AC or 27V AC 

 

   power voltage 230V AC 

 

  4 independent, galvanically separated outputs 

 

  4 outputs protected independently by 1A fuses 

 

  jumper selectable fuse type: glass fuse or     
polymer fuse 

 

LED indication  

 
 

 

AW technical output indicating AC power loss - 

relay  

 

protections: 

 

SCP short-circuit protection 

 

overvoltage protection   

 

OLP overload protection 

 

against tampering 

 

OHP overheat protection of transformer 

 

warranty – 5 year from the production date 

 

 
CONTENTS: 
1. Technical description. 

1.1. General description 
1.2. Block diagram 
1.3. Description of PSU components and connectors 
1.4. Specifications 
2. Installation. 
2.1. Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1. LED indication

  

3.2. Technical output 

4. Operation and use. 

4.1. Overload and short-circuit 

 

4.2. Maintenance 

 

 
1. Technical description. 
 

1.1. General description. 
The AC/AC  PSAC 04244  PSU  intended for supplying CCTV system devices requiring  voltage of 24V  AC 

or 27V AC and total capacity of 4A@24V AC.It features 4 outputs protected independently, galvanically separated  
with  glass  or  polymer  fuses.  Output  voltage  range  is  step-adjustable  by  appropriate  jumpers,  independently  for 
each  AUX  output.  The  PSU  is  housed  in  a  metallic  enclosure  that  features  a  microswitch  indicating  unwanted 
opening of the front door (faceplate). 
 
1.2. Block diagram (fig.1). 

 

Fig.1. Block diagram of the PSU 

Summary of Contents for PSAC 04244SEP

Page 1: ...PSAC 04244SEP v 1 0 PSAC 24VAC 4A 4x1A SEP AC power supply for CCTV EN Edition 2nd 05 Jul 2012 Supersedes the 1st 1 from 06 Dec 2011 edition...

Page 2: ...of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical output 4 Operation and us...

Page 3: ...g 2 the set of contacts indicates potential free status which corresponds to power supply failure 7 Jumper based fuse selection glass fuse or polymer fuse Fx Fx x Fx jumper on glass fuse selected Fx F...

Page 4: ...www pulsar pl PSAC04244SEP 4 Fig 3 View of the PSU s panel Fig 4 The view of the power supply...

Page 5: ...l free status which corresponds to power supply failure LED indication LED L1 L4 green LED LAW red status of OUT1 OUT4 normal status illuminated failure status not illuminated failure indication of mi...

Page 6: ...cted location and connect the wires 3 Connect the power cables 230V AC with L N power supply terminals Connect the ground wire to the terminal marked by the earth symbol Use a three core cable with a...

Page 7: ...tion and use 4 1 Overload or short circuit at the PSU output The OUT1 OUT4 outputs are protected against a short circuit with glass or polymer fuses In case of fuse damage the replacement of the same...

Page 8: ...ccepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 8 The warranty doe...

Reviews: