![Pulsar PG15KVTWB Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/pulsar/pg15kvtwb/pg15kvtwb_operators-manual_1624752013.webp)
12
CLOSED
CHOKE KNOB
OPEN
CHOKE K
RUN
STOP
STAR
ENGINE SWITCH
OPERATION
3. Pull the choke knob to the CLOSED position to start a cold engine.
Leave the choke knob in the OPEN position to restart a warm engine.
4. Start the engine. Turn the engine switch to the START position, and hold
it there until the engine starts. When the engine starts, release the key,
allowing the switch to return to the
RUN
position.
If the engine fails to start within 5 seconds, release the key, and wait at
least 10 seconds before operating the starter again.
Using the electric starter for more than 5 seconds at a time will Overheat the starter motor and can damage it.
5.
If the choke knob was pulled to the CLOSED position to start the engine,
gradually move it to the OPEN position as the engine warms up.
6. Generator needs to operate for 3-5 minutes without load, then
it can out put power.
NOB
STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use
the following procedure.
1. Move the circuit breaker to the OFF position.
ON
OFF
CIRCUIT
BREAKER
NOTICE