Pulsar PG15KVTWB Operator'S Manual Download Page 12

11 

OPERATION

 

SAFE OPERATING PRECAUTIONS

 

Before operating the generator for the first time, please review the GENERATOR SAFETY section and the chapter titled 
BEFORE  OPERATION. 
For your safety, do not operate the generator in an enclosed area such as a garage. Your generator’s exhaust contains 
poisonous carbon monoxide gas that can collect rapidly in an enclosed area and cause illness or death. 

Before connecting an AC appliance or power cord to the generator: 

Use grounded 3 prong extension cords for single phase generator and 5 prong extension cords for three generator,
tools, and appliances, or double insulated tools and appliances.

Inspect cords and plugs, and replace if damaged.

Make sure that the appliance is in good working order. Faulty appliances or power cords can create a potential for
electric shock.

Make sure the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed the
maximum power rating of the generator. Power levels between rated and maximum may be used for no more than
30 minutes.

Operate the generator at least 1 meter away from buildings and other equipment.

Do not operate the generator in an enclosed structure.

ON 

STARTING THE ENGINE

 

1.

Make sure that the circuit breaker is in the OFF position.

The generator maybe hard to start if a load is connected.

OFF

 

CIRCUIT 

BREAKER

 

2

-1

.

 

Turn the fuel valve lever to the ON position

 (

w

hen using gasoline).

OFF 

ON

 

FUEL VALVE LEVER

 

2-2.   Connect LPG (

w

hen using gasoline)

Connect the LPG connecting pipe to the

LPG port of

 

generator and tighten it;

Connect the LPG connecting pipe to the

LPG 

tank

 and

 

tighten it;

Open the fuel valve switch on LPG 

tank

.

2-1. Gasoline

2-

2

LPG

Summary of Contents for PG15KVTWB

Page 1: ...Model PG15KVTWB www pulsar products com Generator OPERATOR S MANUAL...

Page 2: ...isfaction and will be pleased to answer your questions and concerns A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important And using this generator safely is an important res...

Page 3: ...System 9 Ground Terminal 9 Fuel Gauge 9 VoltMeter 9 Hour Meter 9 BEFORE OPERATION 10 ARE YOU READY TOGET STARTED 10 Knowledge 10 IS YOUR GENERATORREADY TOGO 10 Check the Engine 10 Check the Battery 1...

Page 4: ...NG 22 SPARKPLUG SERVICE 23 BATTERY SERVICE 24 BatteryRemoval 24 BatteryCharging 25 STORAGE 26 STORAGE RECAUTION 26 Cleaning 26 Fuel 26 STORAGE PROCEDURE 27 STORAGE PRECAUTIONS 28 REMOVALFROMSTORAGE 28...

Page 5: ...e in wet conditions such as rain or snow or near apool or sprinkler system or when your hands are wet could result in electrocution Keep the generator dry If the generator is stored outdoors unprotect...

Page 6: ...partially enclosed area the air you breathe could contain a dangerous amount of exhaust gas Never run your generator inside a garage house or near open windows or doors Do not connect to a building s...

Page 7: ...Use the illustrations on these pages to locate and identify the most frequently used controls CONTROL PANEL LPG PORT THE FIRST STAGE REGULATOR THE SECOND STAGE REGULATOR HOUR METER CIRCUIT BREAKER ENG...

Page 8: ...7 CONTROLS FEATURES CYLINDER CRANIUM AIR CLEANER OIL TANK CAP EMPTY FULL OIL GAUGE OIL LEVEL DIPSTICK BATTERY OIL DRAIN TUBE STARTER MOTOR...

Page 9: ...ing and for restarting a warm engine EngineSwitch The engine switch controls the ignition system and it operates the electric starter FUEL VALVE LEVER CHOKE KNOB STOP Stops the engine The engine switc...

Page 10: ...es that apply to the intended use of the generator Attention It is compulsorily to make protective earthing before operating the generator Protective earthing must correspond to Rules for Installing E...

Page 11: ...ake care of any problem you find or have your servicing To prevent a possible fire keep the generator at least 1 meter away from building walls and other equipment during operation Do not place flamma...

Page 12: ...Faulty appliances or power cords can create a potential for electric shock Make sure the electrical rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power...

Page 13: ...release the key and wait at least 10 seconds before operating the starter again Using the electric starter for more than 5 seconds at a time will Overheat the starter motor and can damage it 5 If the...

Page 14: ...sconnect the appliance and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded Substantial over loading may damage the generator Marginal ov...

Page 15: ...to 30 minutes Maximum poweris 60Hz 15 kVA GAS 13 5 kVA LPG For continuous operation longer than 30 minutes do not exceed the rated power Rated poweris 60Hz 12 kVA GAS 11 kVA LPG NOTICE High Altitude O...

Page 16: ...trician and must comply with all applicable laws and electrical codes In some areas generators are required by law to be registered with local utility companies Check local regulations for properregis...

Page 17: ...emperature operation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs anduse Remember that your servicing dealer knows your generator...

Page 18: ...NCESCHEDULE NOTE Replace the paper element only 1 Service more frequently when used industry areas 2 These items should be serviced by your servicing dealer unless you have the proper tools and are me...

Page 19: ...fuel is not covered underwarranty NOTE Gasoline spoils very quickly depending on factors such as light exposure temperature and time In worst cases gasoline can be contaminated within 30days Using co...

Page 20: ...fuel from an unfamiliar station try to find out If the fuel contains alcohol if it does confirm the type and percentage of alcoholused If you notice any undesirable operating symptoms while using a g...

Page 21: ...ible with the environment We suggest you take it in a sealed container to your local service station or recycling center for reclamation Do not throw it in the trash pour it on the ground or pour it d...

Page 22: ...vice category are on the API label on the oil container AIR CLEANERSERVICE 1 Release four latch tabs from the air cleaner cover and remove the cover 2 Foam airfilter a Remove the foam air filter from...

Page 23: ...nance Schedule 1 Clean the foam air filter in warm soapy water rinse and allow to dry thoroughly or clean in non flammable solvent and allow todry 2 Dip the foam air filter in clean engine oil then sq...

Page 24: ...plug wrench commercially available 3 Inspect the spark plugs Replace them if the electrodes are worn or if the insulator is cracked chipped or fouled 4 Measure the spark plug electrode gap with a wir...

Page 25: ...p or other container for at least fifteen minutes Water under pressure can damage the eye Immediately call aphysician Skin Remove contaminated clothing Flush the skin with large quantities of water Ca...

Page 26: ...f the battery s ampere hour rating 1 Connect the battery charger following the manufacturer sinstructions 2 Chargethebattery 3 Clean the outside of the battery and the battery compartment with a solut...

Page 27: ...l tank with fresh gasoline If only partially filled air in the tank will promote fuel deterioration during storage If you keep a container of gasoline for refueling be sure that it contains only fresh...

Page 28: ...engine and place it in a suitable container c Loosen the carburetor drain screw d Drain the gasoline from the carburetor into the container e Tighten the carburetor drain screw securely 2 Change the...

Page 29: ...valve lever in the OFF position to reduce the possibility of leakage Place the generator on a level surface Tilting can cause fuel or oil leakage With the engine and exhaust system cool cover the gene...

Page 30: ...tem can burn you and can ignite some materials Keep the generator level when transporting to reduce the possibility of fuel leakage Move the fuel valve lever to the OFF position When using ropes or ti...

Page 31: ...Gap or replace spark plug p 23 Spark plug wet with fuel floodedengine Dry and reinstall sparkplug 5 Take generatorto an authorized THIS servicing dealer or refer to shop manual Fuel filter restricted...

Page 32: ...on afterstarting Switch circuit breaker ON 2 Check the powertool or appliance at a known good AC powersource Faulty power tool orappliance Replace or repair power tool or appliance Stop and restart th...

Page 33: ...difications to the carburetor If you always operate your generator at altitudes above 1 500 meters have your authorized THIS servicing dealer perform this carburetor modification Even with carburetor...

Page 34: ...ximatly 1 6L Fuel TankCapacity 40L Spark Plug F7TC NHSPLD Battery 12V 21AH Generator Model Single phase AC output Rated voltage 120V 240V Rated frequency Rated Ampere 100A 50A Rated output 12kW GAS 11...

Page 35: ...34 TECHNICAL INFORMATION WIRING DIAGRAM...

Page 36: ...components parts and labor Year 2 Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercia...

Page 37: ...e United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under thi...