PG1202S MANUAL
Grounding the Generator
The ground terminal located on the side of the generator frame must always be used
to connect generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects
to the terminal between the lock washer and nut. Tighten the nut securely to ensure
proper connection. Grounding the generator protects you from electric shock that
results from a build up of static electricity or undetected ground faults.
How to Start Engine
WARNING!
Generator must be properly grounded to prevent electrocution.
•
Only operate generator on a level surface.
•
Always connect the nut and ground terminal on the frame to an appropriate ground source.
Before starting please make sure you have the correct gasoline and oil mixture in 50:1.
Turn the engine
ON/OFF switch to
the “ON” position.
All electrical loads
MUST be
disconnected from
generator.
Turn fuel valve to
the “ON” position
Move the Choke
lever to the
“CLOSED” position.