1.4 Specifications: 

- electrical parameters (tab.2) 
- mechanical parameters (tab.3) 
- operating parameters (tab.4)

 

 
Electrical parameters (tab. 2). 

Mains supply 

20V

÷22V AC  

50VA min. (e.g. AWT5161820, AWT037) 

Current up to 

2,5A max.  

Power frequency 

50Hz 

Power 

34 W 

Efficiency 

83% 

Output voltage 

11V÷ 13,8V DC – buffer operation 
10V÷ 13,8V DC – battery-assisted operation 

Output current 

2A + 0,2A battery charge 
1,7A + 0,5A battery charge 

Voltage adjustment range 

12V÷ 14,5V DC  

Ripple 

40 mV p-p max. 

Current consumption by PSU module systems 

16 mA 

– battery operation 

Battery charging current 

0,2A / 0,5A  -  jumper selectable I

BAT

 

Short-circuit protection SCP  

Electronic - current limitation and/or activation of the F

BAT

 

melting fuse in the battery circuit (failure requires fuse 
replacement). Automatic return. 

Overload protection OLP 

110% ÷ 150% (@25ºC) of power supply, manual restart (the 
fault requires disconnection of the DC output circuit) 

Battery circuit SCP and reverse polarity 
protections 

3,15A - current limitation, F

BAT

 fuse (in case of a failure, fuse-

element replacement required) 

Technical outputs: 
- FAC; output indicating AC power failure  

 
- relay type R: 1A@ 30VDC/50VAC, time lag: approx. 10s. 
 

F

BAT  

fuse 

F3,15A / 250V  

 
Mechanical parameters (tab. 3). 

Dimensions 

L=85, W=63, H=40 [+/- 2mm] 

Fixation 

Dowel pins  x4 (PCB fi=4,2 mm) 

Net/gross weight 

0,08kg/0,13kg 

Connectors 

Outputs: 

Ф0,41÷1,63 (AWG 26-14) 

Battery output BAT: 6,3F-2,5, 30cm 

 

 

 
Operating parameters (tab. 4). 

Environmental class 

II 

Operating temperature 

-

10ºC...+40ºC  

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 
 
 

Summary of Contents for MSR 2012

Page 1: ...MSR 2012 v 1 0 MSR 13 8V 2A Buffer switch mode power supply module with technical output FAC EN Edition 3 from 21 11 2016 Supersedes the edition 2 from 11 05 2015 ...

Page 2: ...scription of components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical outputs 4 Operation and use 4 1 Overload or short circuit of the PSU module output 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU module is intended for an uni...

Page 3: ... AUX DC supply output AUX U AUX GND FAC AC absence technical output relay type CAUTION In Fig 2 the contact set in the potential free status corresponds to a state with no AC power AC power failure 4 LEDs optical indication AC AC voltage LB battery charge AUX output voltage DC 5 Connector to the external LED indicators 6 IBAT jumper battery charging current selection IBAT Ibat 0 2A IBAT Ibat 0 5A ...

Page 4: ...ement Automatic return Overload protection OLP 110 150 25ºC of power supply manual restart the fault requires disconnection of the DC output circuit Battery circuit SCP and reverse polarity protections 3 15A current limitation FBAT fuse in case of a failure fuse element replacement required Technical outputs FAC output indicating AC power failure relay type R 1A 30VDC 50VAC time lag approx 10s FBA...

Page 5: ...ct the device cables to the technical outputs FAC sygnalizacja stanu AC alarm panel controller indicator LED itp 7 Using the IBAT pins determine the maximum battery charging current the should be determine in accordance with battery parameters 8 Make the connections between the battery and the power supply panel paying special attention to the correct polarity 9 Connect the 230V AC power to the tr...

Page 6: ...assisted operation The PSU module is not equipped with a discharged battery disconnection system 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU module from the power supply network The PSU module does not require performing any specific maintenance measures however in the case of significant dust rate its interior is recommended to be cle...