1.3. Description of components and connectors
Table 1. Elements of the PSU module pcb (refer to fig. 2).
Element no.
Description
[1]
V
ADJ
potentiometer, voltage adjustment DC
[2]
F
BAT
fuse in the battery circuit
[3]
Connectors:
+BAT- DC supply output of the battery
(+BAT= red, -BAT=black)
+AUX- DC supply output
(+AUX= +U, -AUX=GND)
FAC - technical output for no AC network - relay type
In Figure 2 configuration of contacts shows relay voltage-free state, which corresponds to the state
signalling no AC network (AC network failure)
[4]
LED indication:
AC - LED for AC voltage
LB - LED for battery charge
AUX - LED for DC voltage
[5]
Connector to an external LED indicators: AC and AUX
[6]
I
BAT
; pins – battery charging current selection
•
I
BAT
=
Ibat =0,2A
•
I
BAT
=
Ibat =0,5A
Legend:
jumper installed
jumper removed
Fig.2. View of the PSU module