background image

www.pulsar.pl                                                      HPSBOC5012C            

 

 

9

 

 

 

WEEE MARK 

 

According to the EU WEE Directive – It is required not to dispose of electric or 

electronic waste as unsorted municipal waste and to collect such WEEE separately. 

 

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled 

according to the applicable law. 

 

 
 

 
 
 
 

 

 

 

 

 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

GENERAL WARRANTY CONDITIONS 

1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a three-year warranty for the equipment, , counted from the device’s 
production date. 
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1).  
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however 
not later that within 14 days from the delivery to the service centre of the manufacturer.  
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 
9. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
11. The manufacturer takes no reponsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

 

Summary of Contents for HPSBOC 7012C

Page 1: ...HPSBOC 7012C v 1 0 HPSBOC 13 8V 6A 17Ah OC Buffer switch mode power supply unit with automatic operation control EN Edition 1 from 22 01 2013 Supercedes...

Page 2: ...SU output SCP on 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised vol...

Page 3: ...1 The block diagram of the PSU 1 3 Description of the module s components and connectors Table 1 Elements of the module s see fig 2 Element no Description 1 LED indicating presence of AC power 2 LED...

Page 4: ...4 Fig 2 The view of the PSU Description of PSU components and connectors tab 2 fig 3 lement no Fig 3 Description 1 PSU module 2 TAMPER contact sabotage protection NC Tab 3 Output terminals of the PSU...

Page 5: ...n system TAMPER indicating unwanted opening of the PSU s enclosure a microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication AC diode indicating AC power status AUX diode indicating DC...

Page 6: ...llation 2 1 Requirements The buffer PSU shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations required and n...

Page 7: ...It can cause a device failure or an electric shock 4 Connect the receivers cables to the terminals V V of the PSU module 5 Connect the power 230V 6 Connect the battery mind the colours battery output...

Page 8: ...OC type output Under normal status UBAT 11 5V the output is connected to ground L level 0V In case of decrease of battery voltage UBAT 11 5V the output is switched into high impedance state hi Z Fig 4...

Page 9: ...at within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs...

Reviews: