background image

www.pulsar.pl                                                                 HPSB3512B                                              

GREEN POWER

 

 

6

 

RED LED: 

 

on – the PSU is supplied with 230V AC  

 

off – no 230V AC supply  

 

GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

 

 
Before installation, prepare a PSU load balance. During normal operation, the total current drawn by 

the  device  may  not  exceed  I=3A*.    Maximum  battery  charge  current:  0,5A*.  Total  device  current  +  battery: 
3,5A max

*

 
As  the  PSU  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch,  therefore  an 

appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed 
about  the  method  of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The  electrical 
system shall follow valid standards and regulations. 
 

2.2 Installation procedure. 

 

1. Before installation, cut off the voltage in the 230V power-supply circuit.

 

2. Mount the PSU in a selected location and connect the wires. 
3. Connect the power cables (~230Vac) to L-N clips of the PSU. Connect the ground wire to the clip marked by the 
earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. Lead 
the cables to the appropriate clips through the insulating bushing of the connection board. 
 

 

                 The  shock  protection  circuit  shall  be  performed  with  a  particular  care,  i.e.  the  yellow  and  green                        

wire coat of the power cable shall stick to one side of the terminal - 

marked with ‘

 symbol on the 

PSU  enclosure.  Operation  of  the  PSU  without  the  properly  made  and  fully  operational  shock 
protection circuit is UNACCEPTABLE! It can cause a device failure or an electric shock

.  

 

 

4. Connect the power (~230V) 
5. Check the PSU output voltage: 
- the PSU voltage without load should amount to U=13,8V DC. 
6. Connect the battery (mind the colours):   
- battery output (+V):  BAT+ cable / red, 
- battery output (0V):  BAT 

– cable / GND / black. 

7. Connect the 

receivers’ cables to the terminals V+ (+), V-(-)  of the PSU module. 

8. Check the PSU operation indicator: green LED. 
9. After installing and checking proper working, the enclosure can be closed. 
 

 
3. Operating status indication. 

 
3.1 LED indication of operating status. 

The  is equipped with two diodes on the front panel:

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                 

*

 

Refer to chart 1

 

Summary of Contents for HPSB 3512B

Page 1: ...HPSB 3512B v 1 0 HPSB 13 8V 3A 7Ah Buffer switch mode power supply unit EN Edition 1 from 19 02 2016 Supercedes the edition...

Page 2: ...status 4 Operation and use 4 1 Overload or short circuit of the PSU output SCP on 4 2 Disconnection of discharged battery 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU i...

Page 3: ...ab 2 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact sabotage protection NC 7 Additional connector for LED indi...

Page 4: ...refer to chart 1 Voltage adjustment range 12 14VDC Ripple 120mV p p max Battery charge current 0 5A max 7Ah 5 Short circuit protection SCP electronic automatic return Overload protection OLP 105 150 o...

Page 5: ...in 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 M 500V DC Operating parameters tab 6 Operating temperature 10 C 40 C see chart 1 Storage...

Page 6: ...L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE Use a three core cable with a yellow and green PE protection wire to make the connection Lead the cables to the a...

Page 7: ...d with the discharged battery disconnection system During the battery assisted operation reducing voltage below 9 5V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and a...

Page 8: ...14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the...