background image

www.pulsar.pl                                                             PSDCB09125C         

 

 

7

 

RED LED: 

 

on 

– the PSU is supplied with 230V AC  

 

off 

– no 230V AC supply  

 

GREEN LED: 

 

on 

– DC voltage in the AUX output of the PSU 

 

off 

– no DC voltage in the AUX output of the PSU 

 

 
4. 

Connect the receivers’ cables to the 

AUX1…AUX9 

connectors on the

 

LB9.

 

5. Connect the power (~230V) 
6. Connect the battery (mind the colours):   
- battery output (+V):  BAT+ cable / red, 
- battery output (- V):  BAT 

– cable / GND / black. 

7. Check the PSU operation indicator: green LED. 
8. Check the PSU output voltage: 
- the PSU voltage without load should amount to U=13,8V DC.   
9. After installing and checking proper working, the enclosure can be closed. 

 
3. Operating status indication. 

 
3.1 LED indication of operating status. 

The PSU is equipped with two diodes on the front panel:

 

 
 
 
 
 
 

 
 
 
4. Operation and use. 

 
4.1 Overload or short circuit of the PSU output (SCP on) 

The 

AUX1 ÷ AUX9

 PSU outputs  are protected against a short circuit by glass fuse.

 

 In case of fuse damage, the replacement of the same parameters is required. 
 
In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The 
restoration of the voltage takes place immediately after the failure (overload) is over. 
 

4.2 Battery-assisted operation.  

In case of a main power outage, the device is immediately switched into a battery-assisted operation. 

 

 
The  PSU  is  equipped  with  the  discharged  battery  disconnection  system.  During  the 

battery-assisted  operation,  reducing  voltage  below  9,5V  at  the  battery  terminals  will cause 
battery disconnection. 

 

 

4.3 Maintenance. 

Any and all maintenance operations may be performed following the disconnection of the PSU from the 

power supply network. The PSU   does not require performing any specific maintenance measures, however, in 
case of significant dust rate, its interior is recommended to be cleaned with compressed air. In case of fuse 
replacement, use a replacement of the same parameters. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Summary of Contents for GREEN POWER CCTV PSDCB09125C

Page 1: ...PSDCB09125C v 1 0 PSDCB 13 8V 5A 9x0 5A 17Ah Buffer power supply for up to 9 analog cameras EN Edition 5 from 25 05 2015 Supercedes the edition 4 from 16 12 2014 GREEN POWER CCTV ...

Page 2: ...tections SCP short circuit protection OVP overvoltage protection overvoltage protection against sabotage overload protection OLP warranty 2 year from the production date An example of power supply for analog cameras range 12V 15V DC 9 x 0 5A CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation ...

Page 3: ...tivated immediately The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 9003 which can accommodate a 17Ah 12V battery A micro switch indicates door opening front cover 1 2 Block diagram fig 1 Fig 1 The block diagram of the PSU 1 3 Description of PSU components Table 1 Elements and connectors of the fuse block tab 1 fig 2...

Page 4: ... 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Ibat Selection jumper for charging current Ibat 1A Ibat 2A Legend jumper installed jumper removed Factory settings Ibat 1A jumper installed 9 fuse block LB9 Fig 3 The view of the PSU ...

Page 5: ...system TAMPER indicating unwanted opening of the PSU s enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off F1 F9 fuse F 0 5A 250V Mechanical parameters tab 4 Enclosure dimensions 280 x 292 x 80 8 mm WxHxD Fixati...

Page 6: ...A battery charge Total device current battery 7A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow ...

Page 7: ...U outputs are protected against a short circuit by glass fuse In case of fuse damage the replacement of the same parameters is required In case of overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immed...

Page 8: ...days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer...

Reviews: