background image

www.pulsar.pl                                                      POE042455B   

GREEN POWER CCTV PoE

 

 

 

10 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household 

waste. According to the European Union WEEE Directive, waste electrical and electronic 

equipment should be disposed of separately from normal household waste. 

 

 

CAUTION!

 

The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must 

not be thrown but recycled according to the applicable law. 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

GENERAL WARRANTY CONDITIONS 

 
1. Pulsar (manufacturer) grants a two-year quality warranty for the equipment, starting from the production date. 
2.  The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the 
manufacturer) if the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that 
such defects have been reported within the warranty period (point.1). 
3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the 
manufacturer. 
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the 
defect.  
5.  Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, 
however not later that within 14 days from the delivery to the service centre of the manufacturer. 
6.  The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, 
or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 
7.  All the services are carried out at the service centre of the manufacturer, exclusively. 
8. The warranty does not cover the defects of the equipment, resulting from:  
- reasons beyond the manufacturer's control,  
- mechanical damage,  
- improper storage and transport,  

use that violates the operation manual or equipment’s intended use  

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,   
- improper installation and configuration (failure to follow instruction). 
9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in 
case of damage or modifications to warranty stickers and serial numbers. 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase. 
11.  The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to 
operate the equipment especially when resulting from failure to comply with the recommendations and requirements 
contained in the manual. 
 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel.  (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

E-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

Summary of Contents for GREEN POWER CCTV POE042455B

Page 1: ...POE042455B v 1 0 PoE 27 6V 4x1A 2x7Ah PoE power supply with battery backup EN Edition 5 from 16 03 2016 Supersedes the edition 4 from 25 05 2015 GREEN POWER CCTV PoE...

Page 2: ...upply output 4 2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 4 webcams requiring stabilized voltage of 24V DC 15 The PSU s...

Page 3: ...ains supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal opera...

Page 4: ...operation of the switch mode PSU 3 V ADJ potentiometer regulation of the power supply output voltage 4 Selection jumper for charging current Ibat 0 5 A Ibat 2 A Description jumper on jumper off Factor...

Page 5: ...protection SCP and reverse polarity connection melting fuse Overvoltage protection OVP U 115 150 of the output voltage disconnection of the output voltage automatic return Deep discharge battery prot...

Page 6: ...class with normal relative humidity RH 90 maximum no condensation and temperature range from 10 C up to 40 C The power supply should operate in a vertical position in order to provide free and convec...

Page 7: ...r an electric shock 4 Connect the network cables Ethernet to the PoE module supply voltage is present only at the AUX sockets and the cameras should be connected to them Pin assignment of the AUX and...

Page 8: ...the LED is permanently illuminated No DC no DC voltage at the module input is indicated by turning off the LIN LED LFPS red LED Fig 2 component 10 is not illuminated during normal operation no failur...

Page 9: ...If the PTC polymer fuses are used disconnect the load from the power supply output for approximately 1 minute to restore output voltage the time needed to cool down the PTC fuse In case of melting fus...

Page 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...