background image

www.pulsar.pl

    

 

 

 

BNC08128C 

 

 

G

REEN POWER CCTV BNC

 

 

1.2.  Block diagram. 

 

 

 

Figure 1. Block diagram of the PSU. 

 
1.3.  The description of components and connectors of the PSU. 
 

Table 1. 

Component No. 

[Figure 2] 

Description 

[1], [11] 

LED optical indication: 
green L

IN

  – indication of voltage at the IN input 

red L

AC

  – AC voltage indication  

red L

FPS

  –FPS failure indication 

[2] 

Connector: 
IN –
 power supply of the module (factory setting) 
AC –230V mains supply indication input  

[3] 

F1 ÷ F8 fuses in the AUX1 ÷ AUX8 (+), F1A circuits 

[4] 

Jumper to select melting fuse or PTC polymer fuse 

[5] 

Green LED L1 ÷ L8 – voltage indication at the AUX outputs (during normal 
operation, these LEDs are on) 

[6] 

BNC connector of the video output to the DVR 

[7] 

BNC connector of the video input from the cameras 

[8] 

AUX1÷AUX8 – camera power supply outputs (12÷15V) 

[9] 

FPS – technical output indicating failure – OC type 

[10] 

FPS – technical output indicating failure – relay type 

[12] 

Optional, external optical indication connector (factory setting) 

Table 1. The description of components of the BNC module. 

 

Summary of Contents for GREEN POWER CCTV BNC08128C

Page 1: ...BNC08128C v 1 0 BNC 13 8V 8x1A 17Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 26 11 2013 Supersedes the edition BNC GREEN POWER CCTV...

Page 2: ...2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The buffer power supply is intended for uninterrupted supply of CCTV systems requiring stabilized voltage of 12V DC...

Page 3: ...230V mains supply indication input 3 F1 F8 fuses in the AUX1 AUX8 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L8 voltage indication at the AUX outputs during normal...

Page 4: ...gure 3 Description 1 The module of the switch mode PSU 2 LED light indicating correct operation of the switch mode PSU 3 ADJ potentiometer regulation of the power supply output voltage 4 Selection jum...

Page 5: ...x F 1A or 8 x PTC 1 1A jumper selectable Battery circuit protection SCP and reverse polarity connection polymer fuse Overvoltage protection OVP U 115 150 of the output voltage disconnection of the ou...

Page 6: ...PSU should be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for 230V AC and low voltage installations The unit should be mounted i...

Page 7: ...made and fully operational shock protection circuit is UNACCEPTABLE It can cause damage to the equipment or an electric shock 4 Connect the power supply line and video signal to the BNC module See Fig...

Page 8: ...e of the AUX1 AUX8 outputs off no failure GREEN LED on DC voltage at the AUX1 AUX8 output off no DC voltage at the AUX1 AUX8 output Additionally the PSU is fitted with LED lights inside the enclosure...

Page 9: ...ice and operation 4 1 Overload or short circuit of the power supply output The AUX1 AUX8 outputs of the PSU are protected against short circuit by melting fuse inserts or PTC fuses In case of melting...

Page 10: ...ervice centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...