Pulsar G65BN Operator'S Manual Download Page 7

7

FEATURES

A - ON/OFF Start Switch

B - 3 in 1 Hour Meter

C -120 Volt 30 Amp RV Receptacle

TT-30)   

D - Circuit Breaker

E - 120V / 240V 30 Amp Twist Lock (L14-30) 

F - Grounding Connection

G - 120V NEMA-5 Receptacle

H - 12V DC Output (For Charging Batteries Only) 

I - Low Oil Alert Lamp

J - Fuel Tank

K - Tank Vapor Valve

L - Frame

M- Choke Lever

N - Fuel Valve (ON/OFF) 

O - Air Filter Housing

P - Recoil Starter

Q - Handle

R - Support Leg

S - Oil Fill and Dipstick 

T - No Flat Tires

Summary of Contents for G65BN

Page 1: ...www pulsar products com OPERATOR S MANUAL Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Mod...

Page 2: ...necting Generator to a building Electrical System 11 Operation 12 How to Stop Engine 13 Grounding the Generator How to Start Engine 12 Receptacles and Extension Cords 13 Don t Overload Generator 14 Wa...

Page 3: ...standards set by the U S Agency EPA How to contact us To order parts receive warranty assistance or other services inquiries you can contact us via our website at www pulsar products com or write to...

Page 4: ...ot all inclusive To avoid accidents the user must understand and follow all manual instructions and use good common sense Using a generator indoors CAN KILL YOU IN MINUTES Carbon monoxide gas is a poi...

Page 5: ...t has been running then the fuel cap may be under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the s...

Page 6: ...r will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Only operate generator on a level surface Always connect the nut and ground ter...

Page 7: ...240V 30 Amp Twist Lock L14 30 F Grounding Connection G 120V NEMA 5 Receptacle H 12V DC Output For Charging Batteries Only I Low Oil Alert Lamp J Fuel Tank K Tank Vapor Valve L Frame M Choke Lever N Fu...

Page 8: ...on card 1 Toolkit Spark Plug Wrench 1 1 Washer 2 Description Qty Foot Assembly Bolt 2 4 Funnel Handle Assembly Wheel Assembly Foot Assembly 2 Bushings Flanged Engine oil 1 Two stage regulator 1 OIL 1...

Page 9: ...mbly by inserting a hair pin through hole at the end of the wheel axle clevis pin and pressing until it locks into place Repeat process on the other side of the generator to install the second wheel A...

Page 10: ...ame and tighten with nut Repeat on opposite side Installing The Handles See fig 4 Place generator on a level surface Clean area around oil fill Remove oil fill cap and wipe dipstick clean Screw dipsti...

Page 11: ...onductive area such as metal decking or steel work Never plug electronic devices into generator having frayed worn or bare wires Never touch bare wires or contact receptacles Never permit a child or u...

Page 12: ...s fully at the RUN position See fig 12 Connect the propane hose to the intake nozzle of regulator Open the valve on the LPG tank See fig 8 Slide the choke lever to the Choke position See fig 10 Push t...

Page 13: ...r 120 Volt AC 20 Amp receptacles 120 Volt AC 30 Amp receptacle TT 30R 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30R 12 Volt 8 3 Amp Output For charging batteries only 120 Volt AC 20 Amp re...

Page 14: ...isconnect any electrical devices from generator then switch the generator off urn fuel valve to the OFF position then switch OFF the engine On Off Switch Use the handle to tilt generator until it bala...

Page 15: ...eezer 800 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000...

Page 16: ...of its fluid is 1 260 or higher when measured by a hydrometer It is strongly recommended to use a hydrometer to test for battery charge and condition Be careful to follow the hydrometer manufacturer...

Page 17: ...around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedur...

Page 18: ...Place generator on a level surface Remove the crankcase dipstick Place an oil pan underneath the oil drain hole to collect used oil Remove the oil drain plug and allow oil to drain completely Reinsta...

Page 19: ...k plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equivalent replacement part Spark plug should be replaced annually BOSCH F7TC...

Page 20: ...ing the unit for long periods of time This will help prevent starting problems in the future If the unit is stored with fuel and the fuel becomes stale or turns gummy or to varnish the warranty does n...

Page 21: ...he Engine in this state as this will prevent any corrosion on the cylinder walls if stored for a long period of time Storage and Transportation of the Generator See Fig 21 Remove any debris that has c...

Page 22: ...g 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Engine has...

Page 23: ...DIAGRAMS 23 G65BN...

Page 24: ...ar products com MANUAL DEL USUARIO Advertencia El escape del motor de este producto contiene productos qu micos que el estado de California reconoce que causan c ncer defectos de nacimiento y otros da...

Page 25: ...nerador a un Sistema El ctrico 11 Funcionamiento 12 Apagando ele Motor 13 Toma de tierra el Generador C mo Encienda el Motor 12 Recept culos y Cables de Extensi n 13 No Sobrecargar el Generador 14 Ref...

Page 26: ...blecidas por la Agencia de Protecci n Ambiental Tome nota de la informaci n siguiente al ponerse en contacto con nosotros para recibir servicio o asistencia bajo garant a Este generador es un generado...

Page 27: ...rejillas de ventilaci n y otras aberturas Instale una alarma de mon xido de carbono a pilas cerca de los dormitorios Cuando trabaje en reas donde los vapores puedan ser inhalados use una mascarilla de...

Page 28: ...sito de combustible est vac o y el interruptor 3 en 1 se encuentre en la posici n Off Apagado No supere nunca la potencia amperaje nominales del generador Esto podr a da ar el generador y o los dispo...

Page 29: ...todo momento No utilice nunca el generador bajo la lluvia o en condiciones h medas Use un interruptor de circuito de falla a tierra GFCI en las reas h medas o altamente conductoras tal como cubiertas...

Page 30: ...circuito E 120V 240V 30 amperios twist lock L14 30 F Terminal de tierra G 4 120V Enchufes H Salida de 12V DC I Alerta de aceite J Dep sito de combustible K Respiradero L Marco M Palanca del estrangul...

Page 31: ...n cuidado para evitar golpear el generador 4 Mantenga el generador en la caja para el montaje de las llantas Lista de Embalaje Porfavor revise todas las partes en la lista Comun quese con su vendedor...

Page 32: ...rificio en el extremo del eje de la rueda y presionando hasta que HAGA CLIC Repetir el proceso en el otro lado del generador para instalar la segunda rueda Colocaci n de las Ruedas See fig 1 Fig 1 Pie...

Page 33: ...asegurarse de que no desborde el motor Insertar un embudo en el orificio de la varilla del c rter y llenarlo con aceite de motor de 4 tiempos SEA10W 30 al dep sito vac o o hasta que el aceite llegue...

Page 34: ...e acero Nunca conecte los dispositivos electr nicos en el generador habiendo deshilachados desgastados o con cables pelados Nunca toque los alambres pelados o hacer contacto con los recipientes Nunca...

Page 35: ...nte a la izquierda espere 30 segundos y luego arranque el generador Propano a Gasolina 1 Con el generador en funcionamiento gire la v lvula de suministro de propano completamente a la derecha para cer...

Page 36: ...de parar el motor Nunca arranque o detenga el motor con los dispositivos el ctricos conectados a los recept culos No hacerlo podr a da ar el generador y los dispositivos el ctricos conectados ADVERTE...

Page 37: ...12 Alambre 14 Alambre 16 Moviendo el Generador Desconecte todos los dispositivos electr nicos de generador y luego apague el generador Gire la v lvula del gasolina a la posici n OFF Incline el genera...

Page 38: ...dor Sin Aire HP 600 800 Serrucho 6000 950 Serrucho Circular 7 1400 2300 Serrucho mitra 10 800 1800 Serrucho Tabla Radial de Brazo 1000 2000 Destornillador El ctrico HP 5 4 Amps Martillo Taladro 700 10...

Page 39: ...sin nada conectado al generador Cuando el motor se haya estabilizado enchufe y encienda la primera carga Se recomienda conectar los dispositivos con la salida m s grande primero y la salida m s peque...

Page 40: ...lgun desecho colectado en el generador y alrededor del mofle y controles Use una aspiradora para recoger desechos sueltos Si hay tierra pegada use un cepillo de cerdas Inspeccionar el area de trabajo...

Page 41: ...instalar el tap n del drenaje apriete firmemente Pongale SAE 10W 30 al dep sito vacio hasta que el aceite llegue al borde exterior del orificio orificio de la varilla del c rter Reemplase la varilla d...

Page 42: ...place con un nuevo filtro anualmente Reinstale el filtro de aire para sellar y reemplace el covertor del filtro de aire Examinar bujias vea fig 29 Desconectar el alambre de bujia de la bujia Antes de...

Page 43: ...burador Si siempre opera su generador a altitudes superiores a 5 000 pies 1 500 metros haga que su distribuidor realice esta modificaci n del carburador Este motor cuando se opera a gran altitud con l...

Page 44: ...e la gasolina y para prevenir que haiga acido y dep sitos de gomas en el systema de gasolina y carburador Almacenamiento interior y usar cobertura protectora para proteger de la tierra El generador ti...

Page 45: ...uando se conecta 1 Corto en el circuito de dipositivo 1 Desconecte el dipositivo conectado 2 El Generado esta sobre cargado 2 Vea pagina 17 No Sobre Cargue 3 El tanque de gasolina esta tapado 3 Limpe...

Page 46: ...DIAGRAMA 23 G65BN...

Reviews: