![Pulsar DTS-i 180 UG III Training Manual Download Page 11](http://html1.mh-extra.com/html/pulsar/dts-i-180-ug-iii/dts-i-180-ug-iii_training-manual_1624731011.webp)
Dealer Development Center
22
Schedule Maintenance
Schedule Maintenance
Dealer Development Center
21
Air Filter
Air Cleaner Element Removal
Remove :
• RH side panel by unlocking it with key
Centrifugal Oil Filter Cleaning:
Remove :
• Centrifugal oil filter cover mounting
screws (C) 3 Nos.
• The cover with gasket
• Replace gasket if damaged
• Clean centrifugal oil filter using
Nylon brush/kerosene or Diesel
Remove :
• Clean oil strainer with Kerosene / Diesel blow compressed air and
then refit it.
• Replace oil strainer if found damaged.
Remove :
• 2 bolts (A).
• Air filter cover (B).
Remove :
• Air filter element assembly along with catrej
• Seperate foam filter from the catrej
Note :
• No need of removing flame arrestor
• White colour filter portion towards carburettor side
• Ensure beading placed properly when fitting cover
Pulsar DTS-i UG-III-180cc
Training Notes
Pulsar DTS-i UG-III-180cc
Training Notes
1st Stage:
Clean with Kerosene
Squeeze
Clean with
Kerosene Again
Blow Low Pressure
Compressed Air
3rd Stage:
Dip into
Engine Oil (20W40)
Squeeze and Remove
Excess Oil
Dry with Cotton Cloth
Air Filter Cleaning
Air Filter Element Cleaning and Inspection
Warning :
Clean the element in a well-ventilated area, and make sure
that there are no sparks or flames anywhere near the working area.
Because of the danger of highly flammable liquid, do not use
gasoline/petrol or a low-flash point solvent to clean the element.
Note :
In dusty areas, the element should be cleaned more frequently
than the recommended interval.
After riding through rain or on muddy roads, the element should be
cleaned immediately.
Since repeated cleaning opens the pores of the foam element replace it
with a new one in accordance with the Periodic Maintenance Chart.
Also if there is a brakage in the element material or any other damage
to the element replace the element with a new one.
Clean Air filter element adhering to standard SOP
2nd Stage: