The ChromaBatten300 contains temperature 
sensing circuitry which scales back the current to 
the LEDS if the internal temperature exceeds 
predefined limits.  

 

When  mounting the ChromaBatten300 at an 
angle other than horizontal, it is essential that 
the cable end is  at the lowest point and the 
display at the top  (as shown in the picture to 
the left). 

This mounting arrangement locates the internal 
temperature sensor at the hottest point – the top. 

 

Failure to observe these essential mounting 
arrangements may results in damage to the LEDs. 

CHROMABATTEN300 

ESSENTIAL MOUNTING PRECAUTIONS 

THIS WAY UP 

Summary of Contents for Chromabatten CBAT100

Page 1: ...ChromaFlood and ChromaBatten have a colour code letter This signifies the finished colour of the fixture B Black S Silver Other colours may become available please check with Pulsar if required The ChromaFlood and ChromaBatten have a thermal management system This progressively reduces the power to the LEDs if the internal temperature exceeds limits set by the software Excess temperature will occu...

Page 2: ...he UIM then select 6 or 12 way using the ñ or ò keys When the required chase pattern way number shows in the display press the ü Yes key to save changes or X Back key to restore the previous settings Channel 10 may be set as a Grand Master for the 36 RGB channels only OR as a Global Grand Master for the 36 RGB channels the ALL Red Green and Blue and the Chase Levels To set the required Ch 10 mode ...

Page 3: ...store Factory Default Settings Press the X change key on the UIM then press the ü Yes key to restore defaults or X Back key to exit The factory default settings are DMX Address 1 ChromaZone Mode 46 Channel Channels per Fixture 3 CFLD 9 CBAT Fixture number 1 Chase patterns 12 Way Channel 10 Grand Master for the 36 RGBs only Input Smoothing ON Low Voltage Supply ON DMX Line Termination OFF If NoSign...

Page 4: ...ChromaFlood100 and ChromaFlood200 Mechanical Details ...

Page 5: ...xture 12 Blue 42 Fixture 6 Blue 2 42 Fixture 4 Blue 3 46 Channel Mode 3 Channels Fixture 6 Channels Fixture 9 Channels Fixture 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 1 9 as 9 Channel Mode 10 36xRGBGrand Master 10 36xRGB Grand Master 10 36xRGB Grand Master OR OR OR 10 Global Grand Master 10 Global Grand Master 10 Global Grand Master 11 Fixture 1 Red 11 Fixture 1 Red 1 11 Fixture 1 Red 1 12 Fix...

Page 6: ...1 14 89 228 Rainbow Strobe 13 86 220 White Any Colour Strobe Channels 1 2 3 set colour 83 212 White Any Colour Crossover Channels 1 2 3 set colour 12 80 204 Blue Yellow Wave Reverse 77 196 Blue Yellow Wave Forward 73 188 Green Magenta Wave Reverse 11 70 180 Green Magenta Wave Forward 67 172 Red Cyan AnyCol Op Col Wave Forward 10 64 164 Red Cyan AnyCol Op Col Wave Reverse Channels 1 2 3 set colour ...

Page 7: ...hing t Low Voltage Supply is t DMX Line Termination t VIEW Sig SET No Sig Chan Levels DMX Address n Receiving t X Change X Restore If NoSignal use t Stand Alone Sett ings View Change ChromaZone Mode nn Channels 3 6 9 10 36 42 46 3 6 FLOOD 9 BATTEN 1 12 of 12 1 6 of 6 FLD 1 4 of 4 BAT 6 Way 12 Way CH10 36xRGB GM CH10 Global GM ON Gentle Smooth OFF Fast Video ON OFF ON OFF Stand Alone Mode Last DMX ...

Page 8: ... apparatus before lightning storms or when unused for long periods Refer all servicing to suitably qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped...

Page 9: ...the internal temperature exceeds predefined limits When mounting the ChromaBatten300 at an angle other than horizontal it is essential that the cable end is at the lowest point and the display at the top as shown in the picture to the left This mounting arrangement locates the internal temperature sensor at the hottest point the top Failure to observe these essential mounting arrangements may resu...