Read the Product Instruction Leaflet and this Safety Instructions Leaflet before attempting 
to install or operate this apparatus. 

Keep this leaflet and the Product Instruction Leaflet for future reference. 

Observe ALL warnings indicated by the 

symbol, both in the Product Instruction 

Leaflet and on the apparatus. 

Follow ALL instructions given in the Product Instruction and this Safety Leaflet.  Failure to 
do so may result in serious injury or death. 

Protect the power cord from being walked on or pinched, particularly at plugs, auxiliary 
outputs, and the point where they exit from the apparatus. 

Only use attachments/accessories specified by the manufacturer (Pulsar Light of 
Cambridge Ltd. UK). 

Use only with the stand/bracket or other mounting arrangement specified in the Product 
Instruction Leaflet.  In case of doubt, consult with the manufacturer (Pulsar Light of 
Cambridge Ltd. UK). 

Unplug this apparatus before lightning storms or when unused for long periods. 

Refer all servicing to suitably qualified service personnel.  Servicing is required when the 
apparatus has been damaged in any way, such as power supply cord or plug damaged, 
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped. 

DO NOT block any of the ventilation openings.  Install the apparatus as specified in the 
Instruction Leaflet. 

DO NOT defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug 
has two blades with one wider than the other.  A grounding-type plug has two blades and a 
third grounding prong.  The wide blade or the third prong is for YOUR safety.  If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete unit. 

UNLESS THIS APPARATUS HAS AN IP RATING OF 65 OR GREATER 

 

Clean only with a DRY cloth. 

 

Protect the apparatus from dripping and splashing. 

 

DO NOT place objects containing liquids on the apparatus. 

 

DO NOT use this apparatus near water or in a condensing atmosphere. 

 

Mains Supply Cable colours

 

Green/Yellow  =

Earth / Ground

Brown  = Live / Phase / Hot

Blue = Neutral / Grounded Conductor

IMPORTANT SAFETY INSTRUCTIONS 

Summary of Contents for CBankIP100

Page 1: ...ing or rig mounting The ChromaBank IP has a colour code letter This signifies the finished colour of the fixture e g B Black S Silver The ChromaBank IP has a thermal management system This progressively reduces the power to the LEDs if the internal temperature exceeds limits set by the software Excess temperature will occur if the units are exposed to high ambient temperatures or inadvertently cov...

Page 2: ...6 or 12 way using the or keys When the required chase pattern way number shows in the display press the Yes key to save changes or X Back key to restore the previous settings Channel 10 may be set as a Grand Master for the 36 RGB channels only OR as a Global Grand Master for the 36 RGB channels the ALL Red Green and Blue and the Chase Levels To set the required Ch 10 mode of operation press the or...

Page 3: ...0 300 Chase patterns 12 CBankIP100 12 CBankIP200 300 Channel 10 Grand Master for the 36 RGBs only Input Smoothing ON Low Voltage Supply ON DMX Line Termination OFF If NoSignal use Stand Alone Mode Stand Alone Settings Ch 1 3 0 bits 0 Ch 4 Chase 1 Select Auto Chase Ch 5 Chase 1 Speed 128 bits 50 Ch 6 Chase 1 Level 255 bits 100 Ch 7 46 0 bits 0 Failure of the internal ChromaBank IP 5 Amp 5x20mm Powe...

Page 4: ......

Page 5: ...e Fixture 1 of 2 Fixture 2 of 2 1 6 as 6 Channel Mode 1 6 as 6 Channel Mode 1 6 as 6 Channel Mode 7 Red 1 25 Red 1 7 Fixture 1 Red 1 8 Green 1 26 Green 1 8 Fixture 1 Green 1 9 Blue 1 27 Blue 1 9 Fixture 1 Blue 1 22 Red 6 40 Red 6 40 Fixture 1 Red 12 23 Green 6 41 Green 6 41 Fixture 1 Green 12 24 Blue 6 42 Blue 6 42 Fixture 1 Blue 12 46 Channel Mode ChromaBank IP 100 18 Channels Fixture ChromaBank ...

Page 6: ...rd Use Channel1 14 89 228 Rainbow Strobe 13 86 220 White Any Colour Strobe Channels 1 2 3 set colour 83 212 White Any Colour Crossover Channels 1 2 3 set colour 12 80 204 Blue Yellow Wave Reverse 77 196 Blue Yellow Wave Forward 73 188 Green Magenta Wave Reverse 11 70 180 Green Magenta Wave Forward 67 172 Red Cyan AnyCol Op Col Wave Forward Channels 1 2 3 set colour All 3 at 0 Red Cyan 10 64 164 Re...

Page 7: ...No Sig Chan Levels DMX Address n Receiving t X Change X Restore If NoSignal use t Stand Alone Sett ings View Change ChromaZone Mode nn Channels 3 6 9 10 36 42 46 18 CBankIP100 36 CBankIP200 1or2 of 2 CBankIP100 1 of 1 CBankIP200 6 Way 12 Way CH10 36xRGB GM CH10 Global GM ON Gentle Smooth OFF Fast Video ON OFF ON OFF Stand Alone Mode Last DMX Packet Channel Assignments Tables and Chase Select Table...

Page 8: ......

Page 9: ...suitably qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped DO NOT block any of the ventilation openings Install the apparatus as specified in the In...

Page 10: ......

Reviews: